Skip to content

Lifeline Unipolar J-Lead #483-05

by Intermedics, Inc. 510(k)

Active United States

510(k) K830463

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK830463 Date28 Feb 1983ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Lifeline Unipolar J-Lead #483-05 is a permanent pacemaker electrode, designed for use in cardiovascular applications. It is a unipolar lead intended for implantation within the heart to deliver electrical stimulation for pacing purposes, ensuring proper cardiac rhythm.

This device is supplied sterile and intended for single-use implantation. It is classified as a Class III medical device under FDA regulations and has received 510(k) clearance through a traditional review pathway. The lead is intended for use in MRI-unspecified settings and must be handled according to sterile procedures prior to implantation.

Other devices from Intermedics, Inc.

See all devices from Intermedics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical purpose of the Lifeline Unipolar J-Lead #483-05 and where is it implanted within the body?

    The Lifeline Unipolar J-Lead #483-05 is designed specifically for permanent implantation within the heart to deliver electrical pacing stimulation. It ensures proper cardiac rhythm by providing unipolar pacing, which is essential for patients requiring chronic cardiac rhythm management.

  • Is this device intended for reuse or is it meant to be used only once after opening?

    This device is explicitly intended for single-use implantation only. It is supplied sterile and must not be reused after opening to maintain sterility and ensure patient safety.

  • How should the Lifeline Unipolar J-Lead #483-05 be handled before implantation to ensure proper use?

    The lead must be handled using sterile procedures prior to implantation, as it is supplied in a sterile package. This ensures contamination is avoided and maintains its intended performance for delivering reliable cardiac pacing.

  • What type of regulatory pathway was followed for FDA clearance of this device, and what does that mean for its safety and efficacy?

    The Lifeline Unipolar J-Lead #483-05 received FDA 510(k) clearance through a traditional review pathway, meaning its safety and performance were evaluated by the FDA against legally marketed predicate devices. This process ensures it meets established standards for permanent pacemaker electrodes.

  • Can this device be used in environments where MRI scans are performed, or are there specific restrictions?

    The device is labeled for use in MRI-unspecified settings, meaning its compatibility with MRI environments is not explicitly defined. Clinicians should follow strict protocols and consult manufacturer guidelines to avoid potential risks during MRI procedures, as pacemaker leads may interact with magnetic fields.