LIGAFIX Router bit
by S.B.M 10 variants
Ref LIG9095072Model Cutting instrument for ACL reconstruction
Active
CE MDD
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Overview
LIGAFIX router bit for use with LIGAFIX interference screws in orthopedic surgery. A reusable cannulated surgical drill bit for clearing intramedullary channels.
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-03760154006033 03760154006033 | Date8 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number03760154006033 | Date20 Dec 2023 | StatusListed |
Official records
- EUDAMED public site B-03760154006033
- AccessGUDID record 03760154006033
From the FDA record
- Device description
- LIGAFIX router bit for use with LIGAFIX interference screws for ACL reconstruction.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-03760154006033 registered 8 Oct 2026 Active
- FDA GUDID UDI-DI 03760154006033 listed 20 Dec 2023 Listed
Timeline
- Listed FDA GUDID 03760154006033
- Registered EUDAMED B-03760154006033
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Ligafix® EUDAMEDLigafix GUDID
- Generic name
- Cannulated surgical drill bit, reusable
- Device name
- Cutting instrument
- Model / Ref / Catalog
- Cutting instrument for ACL reconstruction, LIG9095072, Router bit
- Primary DI / UDI-DI
- 03760154006033
- Basic UDI-DI
- B-03760154006033
- FDA product code
- HTW
- EMDN code
- L090999 Orthopaedic surgery cutting instruments, reusable - other
- GMDN term
- Cannulated surgical drill bit, reusable
- Device class
- Class IIa EUDAMEDClass I GUDID
- Regulation number
- 888.4540
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- Size
- Outer Diameter — 9.5 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | Cutting instrument for ACL reconstruction LIG9095072 | Router bit |
| Device class | Class IIa | Class I |
Similar devices in this category
Other devices filed under ORTHOPAEDIC SURGERY CUTTING INSTRUMENTS, REUSABLE - OTHER.
- MICROPLASTY 32-484632 by Biomet Orthopedics, Inc.
- Tap Kirschner Wire Awl 03.161.026 by Synthes GmbH
- PERSONA® 42-5399-018-14 by Zimmer, Inc.
- Persona® 42-5830-075-14 by Zimmer, Inc.
- Conquest Series 0300034602 0300-034-602 by Stryker Corp.
- Gimmi KH.1899.23 by Gimmi GmbH
- Gimmi CY.1710.20 by Gimmi GmbH
- JuggerKnot® 912038P by Biomet Orthopedics, Inc.
- JOURNEY II 74014543 by Smith & Nephew, Inc.
- Crossback Acetabular Reamer 43mm T17612 by Viant Medical, LLC