Light Guide Adapter MAJ-1413

by Olympus Medical Systems Corporation

Light Guide Adapter MAJ-1413 (N1773933) is a light source adaptor (FDA Class II; FDA product code FAJ, Cystoscope And Accessories, Flexible/Rigid) made by Olympus Medical Systems Corporation, cleared under FDA 510(k) K221690 on 29 Dec 2022 and listed in FDA GUDID since 22 Apr 2023 (UDI-DI 04953170434488), active as of 22 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

510(k) K221690

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04953170434488 UDI-DI Date22 Apr 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK221690 Date29 Dec 2022DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K221690 decided 29 Dec 2022 Active
  • FDA GUDID UDI-DI 04953170434488 listed 22 Apr 2023 Listed

Recalls

3 recalls · 3 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-0685-2024 FDA Class II initiated 4 Dec 2023
    • Ongoing Z-0684-2024 FDA Class II initiated 4 Dec 2023

    Olympus has updated the instructions for use: Reusable cleaning brushes have been removed from the manual cleaning. Single use brushes remain compatible.

    • Ongoing Z-0331-2024 FDA Class II initiated 25 Sep 2023

    Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection

Timeline

5 dated events

  1. Cleared FDA 510(k) K221690
  2. Listed FDA GUDID 04953170434488
  3. Recall initiated FDA recalls Z-0331-2024
  4. Recall initiated FDA recalls Z-0685-2024
  5. Recall initiated FDA recalls Z-0684-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Light Guide Adapter
Generic name
Light source adaptor
Model / Ref / Catalog
MAJ-1413, N1773933
Primary DI / UDI-DI
04953170434488
FDA product code
FAJ
GMDN term
Light source adaptor
Device class
Class II
Regulation number
876.1500
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Light source adaptor.

Other devices from Olympus Medical Systems Corporation

See all devices from Olympus Medical Systems Corporation →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)