# Lightspeed 4.0 Ct Scanner System

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/lightspeed-4-0-ct-scanner-system-jak>
- Manufacturer: [GE Medical Systems](https://devicerts.com/manufacturers/ge-medical-systems-inc) (United States)
- Name in the registry: LIGHTSPEED 4.0 CT SCANNER SYSTEM
- Device class: Class II (US FDA)
- FDA product code: JAK

## Overview

*AI-generated summary, 2026-09-23. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Lightspeed 4.0 Ct Scanner System is a computed tomography (CT) scanner. It is a medical device used for diagnostic imaging purposes.

The device is supplied by GE Medical Systems and has been authorized with an FDA 510K clearance. It is classified under product code JAK and has been reviewed by the Radiology advisory committee. The device is available with the model number K013561.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K013561 · decision 2001-11-08 · decision SESE · status: Active

## Recalls

- Z-1048-2016 · Class II · terminated · initiated 2016-02-10: GE Healthcare has updated the Service Manuals for a number of CT and PET CT Scanners to update an incorrect torque value.
- Z-2801-2015 · Class II · terminated · initiated 2015-07-17: Potential for expulsion of the Power Supply on Lightspeed CT scanner or Discovery ST PET CT or Discovery LS PET CT scanner.
- Z-1623-2015 · Class II · terminated · initiated 2015-04-22: GE Healthcare has become aware that 3 bolts that secure a power supply to the rotating side of the gantry were over-torqued on certain Lightspeed 16 CT scanner or PET/CT DST Scanner.. In the unlikely event that the component becomes loose on the CT gantry during operation, it could result in serious bodily injury if the component were expelled. There were no incidents or injuries reported as a res
- Z-1188-2013 · Class II · terminated · initiated 2011-07-25: Fastener bolts on the heat exchanger were not properly torqued and part of the heat exchanger can detach from the gantry and hit the inside of the covers and other components of the gantry possibly resulting in the oil conduit breaking, spilling oil within the gantry and outside the system. This issue affects GE Healthcare VCT for Discovery VCT, Discovery RX VCT, and Discovery PET/CT 690, Lightspe
- Z-0306-04 ·  · terminated · initiated 2003-12-08 · matched through shared submission K013561, may concern other models: Incorrect mounting hardware may cause X-ray tube to separate from the gantry and fall.

## Identifiers

- 510(k) Number: K013561 [FDA 510(k)]
- FDA product code: JAK [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 892.1750 [FDA 510(k)]
- Advisory committee: Radiology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Lightspeed 4.0 Ct Scanner System, GE Medical Systems. deviCERTS medical device catalogue. https://devicerts.com/devices/lightspeed-4-0-ct-scanner-system-jak (data as of 2026-11-23).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-23
- JSON: <https://devicerts.com/devices/lightspeed-4-0-ct-scanner-system-jak.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/lightspeed-4-0-ct-scanner-system-jak
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.