Linical Protein III Calibration Verifiers Levels A-E for Beckman Array Protein System

by International Enzymes, Inc.

510(k) K953926

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK953926 Date15 Sep 1995ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DCK
Device Class
Class II
Regulation
21 CFR Part 866.5270
Advisory Committee
Immunology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

Linical Protein III Calibration Verifiers Levels A-E for Beckman Array Protein System are assayed quality control materials used to verify calibration and assess linearity of Beckman-Coulter Immage™ analytical systems. The device provides known protein concentrations to validate instrument performance and ensure accuracy of clinical laboratory testing.

Supplied as ready-to-use liquid stable human-serum protein matrix, the verifiers are stored at 2-8 °C and intended for use in the clinical laboratory. The device is a Class II medical device with FDA 510(k) clearance (K953926) and product code DCK, regulated under 21 CFR 866.5270 for C-Reactive Protein, Antigen, Antiserum, and Control.

Other devices from International Enzymes, Inc.

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the LINICAL Protein III Calibration Verifiers Levels A-E for the Beckman Array Protein System?

    The LINICAL Protein III Calibration Verifiers are used to verify the calibration and linearity of Beckman-Coulter Immage™ analytical systems. They provide known protein concentrations in a human-serum protein matrix to ensure the accuracy and reliability of clinical laboratory testing for protein assays.

  • How are these calibration verifiers supplied and stored?

    They are supplied as ready-to-use liquid materials in a stable human-serum protein matrix. Storage requires refrigeration between 2-8 °C, making them suitable for use in clinical laboratory settings where temperature control is standard.

  • Are these calibration verifiers intended for single-use or repeated use?

    The device is designed for use in the clinical laboratory to validate instrument performance, but the specific reuse instructions are not detailed in the data. Typically, calibration verifiers like these are used once per calibration cycle or as needed for quality control checks, though proper documentation of usage would be required to ensure compliance with laboratory protocols.

  • What regulatory pathway was followed for FDA clearance of this device?

    The LINICAL Protein III Calibration Verifiers received FDA clearance through a 510(k) submission, classified as Substantially Equivalent (SE) under the Traditional clearance type. The device falls under product code DCK and is regulated under 21 CFR 866.5270, with an advisory committee designation in Immunology. The clearance number is K953926.

  • What types of protein measurements does this calibration verifier support?

    While the device itself is not a measurement tool, it is specifically designed to validate the performance of Beckman-Coulter Immage™ systems for C-Reactive Protein (CRP) and related protein assays. The verifiers ensure the accuracy of quantitative protein measurements in clinical laboratories, particularly those using the Beckman Array Protein System.