LINK Embrace Shoulder System 645-080/30
by WALDEMAR LINK GmbH & Co. KG
Ref 645-080/30Model Glenoid baseplate, uncemented, Ti6Al4V-3D-printed, reverse
LINK Embrace Shoulder System 645-080/30 is a reverse shoulder prosthesis base plate (EU MDR Class III; FDA Class II) made by WALDEMAR LINK GmbH & Co. KG, registered in EUDAMED on 10 Aug 2026 (Basic UDI-DI 4026575-1-OEX-300008-WP) with CE/MDR certificate 057-00-02-MDR valid until 12 Sep 2029, cleared under FDA 510(k) K200368 on 5 Feb 2021 and listed in FDA GUDID since 24 Mar 2021 (UDI-DI 04026575240449), active as of 24 Oct 2026.
Active
CE MDR 510(k)
Valid until
12 Sep 2029
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number4026575-1-OEX-300008-WP 04026575240449 | Date10 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04026575240449 | Date24 Mar 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK200368 | Date5 Feb 2021 | StatusActive |
Official records
- EUDAMED public site 4026575-1-OEX-300008-WP
- AccessGUDID record 04026575240449
- FDA 510(k) database K200368
From the FDA record
- Device description
- Reverse Glenoid Baseplate
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 4026575-1-OEX-300008-WP registered 10 Aug 2026 Active
- FDA 510(k) K200368 decided 5 Feb 2021 Active
- FDA GUDID UDI-DI 04026575240449 listed 24 Mar 2021 Listed
Certificates
- 057-00-02-MDR Active
Technical documentation EU MDR
- Certifier
- ITALCERT SRL 0426
- Issued
- 13 May 2025
- Expires
- 12 Sep 2029
- Reason
- Other
Timeline
- Cleared FDA 510(k) K200368
- Listed FDA GUDID 04026575240449
- Certificate issued EUDAMED 057-00-02-MDR
- Registered EUDAMED 4026575-1-OEX-300008-WP
- Certificate expires EUDAMED 057-00-02-MDR
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- LINK Embrace Shoulder System
- Generic name
- Reverse shoulder prosthesis base plate
- Model / Ref / Catalog
- 645-080/30, Glenoid baseplate, uncemented, Ti6Al4V-3D-printed, reverse
- Primary DI / UDI-DI
- 04026575240449
- Basic UDI-DI
- 4026575-1-OEX-300008-WP
- 510(k) Number
- FDA product code
- HSD, PAO, PHX
- EMDN code
- P09010301 Metal back and metaglene glenoid baseplates
- GMDN term
- Reverse shoulder prosthesis base plate
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 888.3690, 888.3660
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Similar devices in this category
Other devices filed under METAL BACK AND METAGLENE GLENOID BASEPLATES.
- SMR TT Hybrid Glenoid 1379.59.304 by Limacorporate
- DELTA XTEND 1407-60-015 140760015 by DEPUY (IRELAND)
- Shoulder System 04.01.0151 by Medacta International SA
- SMR TT Hybrid Glenoid 1379.15.160 by Limacorporate
- isareverse™ 0022I2615 by MOVE-UP
- Glenoid Reconstruction System 04.01.0308 by Medacta International SA
- Humelock II Cemented Reversible Shoulder 105-0024 by FX SOLUTIONS
- DELTA XTEND 1407-60-010 140760010 by DEPUY (IRELAND)
- Reverse Glenoid Platform T38150025S by Tianjin Zhengtian Medical Instrument Co., Ltd.
- Glenoid Baseplate with Screw 105-0028 by FX SOLUTIONS