Lithium Micro Volume Electrode, Theophylline, ISE Calibrators 1, 2 and 3, TDM Calibration Set B, Nortrol and AbtroL

by Thermo Electron OY

510(k) K063705

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK063705 Date9 Oct 2007ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
NDW
Device Class
Class II
Regulation
21 CFR Part 862.3560
Advisory Committee
Clinical Toxicology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a TDM Calibration Set and Ion Selective Electrode (ISE) Calibrator designed for quantitative measurements in clinical toxicology. It includes lithium micro volume electrodes and calibrators for theophylline, lithium, potassium, sodium, and chloride in human serum or plasma, ensuring accurate assay performance for therapeutic drug monitoring (TDM).

The set is supplied as a reusable calibration tool for laboratory use, with calibrators intended for single-use per bottle or bag. Authorized under FDA 510(k) clearance (K063705), it adheres to Regulation 862.3560 and is classified as Class II. No MRI safety or sterility specifications are stated in the data.

Other devices from Thermo-Electron Corp.

See all devices from Thermo-Electron Corp. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical applications does this calibration set support in a lab setting?

    This TDM Calibration Set is specifically designed for quantitative measurements in clinical toxicology, ensuring accurate assay performance for therapeutic drug monitoring (TDM). It supports calibrations for theophylline, lithium, potassium, sodium, and chloride in human serum or plasma, which are critical for monitoring drug levels in patients to prevent toxicity or under-dosing.

  • Are the calibrators in this set intended for single-use or reusable, and how should they be handled?

    The calibrators in this set are intended for single-use per bottle or bag, meaning each bottle or bag should be used once before disposal. The lithium micro volume electrodes, however, are part of a reusable calibration tool for laboratory use, allowing them to be used across multiple calibration sessions.

  • What sizes or models are included in this calibration set, and how are they differentiated?

    This set includes three calibrators labeled as ISE Calibrators 1, 2, and 3, along with lithium micro volume electrodes. The calibrators are differentiated by their assigned numbers (1, 2, and 3) and are used in conjunction with the electrodes for precise calibration of ion-selective measurements. The set also includes additional components like Nortrol and Abtrol, which are likely reference standards for theophylline and other analytes.

  • How is this device regulated, and what does the FDA clearance indicate about its safety and effectiveness?

    This device is authorized under FDA 510(k) clearance (K063705) and is classified as Class II, indicating it has been determined to be substantially equivalent to a legally marketed device. The clearance process ensures that the device meets regulatory standards for safety and performance, specifically for use in clinical toxicology applications as outlined in the submission.

  • Is this calibration set compatible with any specific laboratory equipment or systems?

    While the data does not specify exact equipment compatibility, this TDM Calibration Set is designed for use with ion-selective electrode (ISE) systems commonly found in clinical laboratories. It is intended to work with standard laboratory tools for therapeutic drug monitoring, ensuring accurate calibration of measurements for theophylline, lithium, potassium, sodium, and chloride in human serum or plasma.