Identity
- Trade Name
- LiverMultiScan FDA UDI
- Generic Name
- Radiology DICOM image processing application software FDA UDI
- Device Name
- LiverMultiScan (LMSv3) is indicated for use as a magnetic resonance diagnostic device software application for non-invasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times. LiverMultiScan (LMSv3) is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MR Systems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced. LiverMultiScan (LMSv3) provides a number of tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2* and iron-corrected T1 (cT1) measurements. PDFF may optionally be computed using the LMS IDEAL or three-point Dixon methodology. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis. FDA UDI
- Model / Reference
- 3.3.0 FDA UDI
- Description
- LiverMultiScan (LMSv3) is indicated for use as a magnetic resonance diagnostic device software application for non-invasive liver evaluation that enables the generation, display and review of 2D magnetic resonance medical image data and pixel maps for MR relaxation times. LiverMultiScan (LMSv3) is designed to utilize DICOM 3.0 compliant magnetic resonance image datasets, acquired from compatible MR Systems, to display the internal structure of the abdomen including the liver. Other physical parameters derived from the images may also be produced. LiverMultiScan (LMSv3) provides a number of tools, such as automated liver segmentation and region of interest (ROI) placements, to be used for the assessment of selected regions of an image. Quantitative assessment of selected regions includes the determination of triglyceride fat fraction in the liver (PDFF), T2* and iron-corrected T1 (cT1) measurements. PDFF may optionally be computed using the LMS IDEAL or three-point Dixon methodology. These images and the physical parameters derived from the images, when interpreted by a trained clinician, yield information that may assist in diagnosis. FDA UDI
Identifiers
- Primary DI / UDI-DI
- B554LMS3300 FDA UDI
- FDA Product Code
- LNH FDA UDI
- GMDN Term
- Radiology DICOM image processing application software FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 892.1000 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
No
FDA UDI
MR Conditional FDA UDI
Category: Radiology DICOM image processing application software
LiverMultiScan by Perspectum — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Radiology DICOM image processing application software.
- Imbio Freya — Imbio, LLC · Class II
- Pacs View — BRIT SYSTEMS · Class II
- XR90 System, LOGIQ, Upgrade Kit — MediView XR · Class II
- OptiVu™ Mixed Reality — Orthosoft Inc · Class II
- PowerLook PRO+ Rack-Mount, OUS — Icad, Inc. · Class I
- Annalise Triage — Annalise-Ai Pty , Ltd. · Class II
- PowerLook PRO+ 4GPU Tower Platform, US — Icad, Inc. · Class I
- PowerLook PRO+ 4GPU Tower Platform, OUS — Icad, Inc. · Class I
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Perspectum
Sources (1)
- FDA UDI f60c9485-d60b-4923-acab-a9901fc93418 34 fields · synced May 31, 2026