Skip to content

Lumatag Intact PTH Assay

by London Diagnostics, Inc.

510(k) K903130

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK903130 Date25 Sep 1990ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
London Diagnostics Lumatag(Tm) Intact Pth Assay
510(k) Number
FDA Product Code
CEW
Device Class
Class II
Regulation
21 CFR Part 862.1545
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Lumatag Intact PTH Assay is a radioimmunoassay designed for the quantitative measurement of intact parathyroid hormone (PTH) in serum or plasma. It employs a luminescent tag to detect and quantify PTH levels, aiding in the diagnosis and monitoring of parathyroid disorders, including hyperparathyroidism and hypoparathyroidism. This assay is classified under clinical chemistry devices and is intended for in vitro diagnostic use.

This assay is supplied as a single-use diagnostic kit and requires laboratory processing. It is regulated under FDA 510(k) clearance (K903130) and falls under the classification of Class II medical devices. The device is intended for use in clinical chemistry laboratories and is not intended for MRI environments. Storage and handling follow standard in vitro diagnostic assay protocols, with sterility maintained through manufacturer-provided packaging.

Other devices from London Diagnostics, Inc.

See all devices from London Diagnostics, Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of samples can the Lumatag Intact PTH Assay measure, and how is it intended to be used in clinical practice?

    The Lumatag Intact PTH Assay is designed to quantitatively measure intact parathyroid hormone (PTH) levels in serum or plasma samples. It is intended for use in clinical chemistry laboratories to aid in diagnosing and monitoring parathyroid disorders, such as hyperparathyroidism and hypoparathyroidism. Since it is a radioimmunoassay, it requires laboratory processing and is not a point-of-care or bedside test.

  • Is the Lumatag Intact PTH Assay intended for single-use, and how should it be stored to maintain sterility?

    Yes, the Lumatag Intact PTH Assay is supplied as a single-use diagnostic kit, meaning each kit is intended for one test procedure only. Sterility is maintained through the manufacturer-provided packaging, and storage should follow standard in vitro diagnostic assay protocols—typically in a clean, dry environment away from direct sunlight or extreme temperatures, as outlined in the manufacturer’s instructions.

  • What regulatory pathway was followed for FDA clearance of this assay, and what classification does it fall under?

    The Lumatag Intact PTH Assay received FDA 510(k) clearance under the traditional review pathway, with a decision date of September 25, 1990. It is classified as a Class II medical device and falls under the Clinical Chemistry advisory committee (CH). The clearance number is K903130, and it is intended for in vitro diagnostic use.

  • Can this assay be used in environments where MRI equipment is present, or does it have any special handling requirements?

    The Lumatag Intact PTH Assay is not intended for use in MRI environments. Since it is a radioimmunoassay, it does not contain MRI-compatible materials, and exposure to magnetic fields could potentially interfere with its performance or safety. Standard laboratory protocols for in vitro diagnostics should be followed, including proper handling and disposal of radioactive materials if applicable.