Skip to content

Lorad M-III Mammographic X-Ray System

by Lorad Corp.

510(k) K934625

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK934625 Date28 Jan 1994ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Lorad M-III
510(k) Number
FDA Product Code
IZH
Device Class
Class II
Regulation
21 CFR Part 892.1710
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Lorad M-III is a Mammographic X-Ray System, designed for digital or analog breast imaging to detect and evaluate breast abnormalities. It operates as a standalone unit, incorporating a C-arm and control console to produce high-resolution mammograms, aiding in the early detection and diagnosis of breast cancer.

This device is intended for use in radiology departments and has received FDA 510(k) clearance (K934625) under the Traditional 510(k) Review Process, classified as a Class II medical device. Supplied as a reusable system, it adheres to regulatory standards outlined in 21 CFR 892.1710 and is manufactured by Lorad Corp. in Danbury, Connecticut. No specific sterility or MRI safety information is provided in the regulatory data.

Other devices from Lorad Corp.

See all devices from Lorad Corp. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of breast imaging can the Lorad M-III perform, and how does it differ from standard analog systems?

    The Lorad M-III is designed for both digital and analog breast imaging, allowing flexibility depending on clinical needs. Unlike purely analog systems, it produces high-resolution mammograms through a standalone C-arm and control console, which enhances image clarity for detecting and evaluating breast abnormalities such as tumors or calcifications. This dual-capability supports early detection and diagnosis of breast cancer while maintaining compatibility with existing workflows.

  • Is the Lorad M-III a single-use or reusable device, and what maintenance considerations should be noted?

    The Lorad M-III is supplied as a reusable system, meaning it is intended for repeated use in radiology departments after proper cleaning and maintenance. Since it is not sterile, it must be handled according to facility protocols for reusable medical devices. Regular servicing and calibration are essential to ensure consistent imaging quality and compliance with regulatory standards (e.g., 21 CFR 892.1710).

  • What regulatory pathway was followed for FDA clearance, and how does this affect its use in clinical settings?

    The Lorad M-III received FDA 510(k) clearance (K934625) under the Traditional 510(k) Review Process, classified as a Class II medical device. This means it was determined to be substantially equivalent to a legally marketed predicate device, ensuring it meets safety and effectiveness standards for mammographic imaging. Clinicians can rely on this clearance to confirm its suitability for breast cancer screening and diagnostic use in radiology departments.

  • Are there multiple models or configurations of the Lorad M-III, and how can I identify the correct one for my facility?

    The Lorad M-III appears to have multiple FEI numbers (e.g., 3001722928, 3009470597) and registration numbers, which may correspond to different configurations or serial batches. These identifiers are used for regulatory tracking and inventory management. To ensure compatibility, verify the exact model or variant with Lorad Corp. or consult your facility’s equipment records, as specifications like C-arm adjustments or software versions may vary slightly.