Skip to content

ImageChecker M1000 System

by Hologic, Inc.

PMA P970058

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

PMA P970058↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPRL NumberP970058 Date26 Jun 1998DecidedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Trade name
M1000 Imagechecker
Generic name
Analyzer, medical image
PMA number
FDA product code
MYN
Device class
Class II
Regulation
21 CFR Part 892.2070
Advisory committee
Radiology
FDA decision
APRL

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The ImageChecker M1000 System is a computer-based medical image analyzer designed to assist radiologists in screening mammograms. It identifies and marks regions of interest on digital images to highlight potential areas that may require a second review, thereby helping to minimize observational oversights during initial readings.

This system is intended for use in radiology settings and operates as a software-based tool integrated with mammography workflows. Supplied as a standalone computer system, it does not require sterilization and is classified as a Class II device under FDA regulations. The system is authorized under a Premarket Approval (PMA) application (PMA P970058) and is intended for use with digital mammographic images.

Other devices from Hologic, Inc.

See all devices from Hologic, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical role does the ImageChecker M1000 System play in mammography workflows and how does it assist radiologists?

    The ImageChecker M1000 System is a computer-based tool designed to assist radiologists by analyzing digital mammographic images and identifying regions of interest that may have been overlooked during the initial review. It marks these areas to flag them for a second look, helping to reduce observational errors and improve diagnostic accuracy in screening mammograms.

  • Is the ImageChecker M1000 System reusable or single-use, and what are the storage requirements?

    The ImageChecker M1000 System is a standalone computer-based device and is not intended for reuse in the traditional sense (e.g., sterilization). Since it is a software-integrated system, it does not require sterilization or single-use packaging. Proper storage involves maintaining the hardware in a clean, controlled environment to prevent dust or damage, ensuring software updates are applied as recommended by the manufacturer.

  • What regulatory pathway was followed for the approval of the ImageChecker M1000 System, and what does this mean for its use?

    The ImageChecker M1000 System was authorized through the FDA’s Premarket Approval (PMA) process, specifically under PMA P970058. This means the device underwent rigorous review by the FDA to ensure its safety and effectiveness for its intended use—assisting radiologists in screening mammograms by identifying potential areas of concern in digital images. Clinicians can rely on this approval as evidence of the system’s validated performance.

  • How is the ImageChecker M1000 System supplied, and what types of digital mammographic images is it compatible with?

    The ImageChecker M1000 System is supplied as a standalone computer system, meaning it comes pre-installed with the necessary software and hardware to operate independently within radiology settings. It is specifically designed to work with digital mammographic images, as outlined in its intended use, and is not compatible with analog or non-digital imaging formats.

  • What are the key specifications or identifiers for the ImageChecker M1000 System in regulatory databases?

    The ImageChecker M1000 System is classified under the FDA’s product code MYN and is listed in OpenFDA with multiple registration numbers (e.g., 3017840913, 3024891354, etc.), reflecting its various configurations or software versions. It falls under the Radiology advisory committee (RA) and is categorized as a Class II medical device, indicating moderate regulatory oversight. These identifiers help track its compliance and submission history.