m2000 08N89-001

by Abbott Molecular

m2000 08N89-001 is a laboratory analyser operation system software IVD (FDA Class II; FDA product code OOI, real time Nucleic acid amplification system) made by Abbott Molecular, cleared under FDA 510(k) K092705 on 28 May 2010 and listed in FDA GUDID since 30 Apr 2015 (UDI-DI 00884999043503), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

510(k) K092705

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00884999043503 UDI-DI Date30 Apr 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK092705 Date28 May 2010DecidedStatusActive

Official records

From the FDA record

Device description
m2000rt SYSTEM SOFTWARE Release 8.0
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K092705 decided 28 May 2010 Active
  • FDA GUDID UDI-DI 00884999043503 listed 30 Apr 2015 Listed

Recalls

7 recalls · FDA

    • Terminated Z-0463-2015 FDA Class II initiated 23 Oct 2014 on shared 510(k) K092705

    Some versions of Application Specifications (App Spec) are incompatible with m2000sp system software version 6.0 and 7.0. This issue will cause Error Code 9000 (An unexpected error has occurred: Software error) to be generated when the Available Reagent Packs screen is selected.

    • Terminated Z-2169-2014 FDA Class II initiated 19 Jun 2014 on shared 510(k) K092705

    Abbott Molecular identified that some of the 5 ml Reaction Vessels (RVs) contained in lots 56944001, 57026001, 57059001, and 57673001 (original vendor lot 2198077) may have an insufficient rim. An RV with an insufficient rim may not be held securely in the 1 mL Subsystem Carrier. This may cause the RV to be seated incorrectly in the carrier or drop through it.

    • Terminated Z-0948-2015 FDA Class II initiated 23 Nov 2013 on shared 510(k) K092705

    The x-drive assembly may fail prematurely. This could cause the manipulator or liquid handling arm to contact an object, shake and drip, or improperly pipet.

    • Terminated Z-0634-2013 FDA Class II initiated 4 Dec 2012 on shared 510(k) K092705

    An issue with the m2000sp Instrument software has been identified whereby, after a series of steps, if changes are made to the control or calibrator information on the Sample Extraction Assay Details screen, the changes are not saved.

    • Terminated Z-2013-2012 FDA Class II initiated 31 Jan 2012 on shared 510(k) K092705

    In the Abbott Molecular Bar Code Scanner User's Guide, List Number 6L88-02/09, the section Modifying the Keyboard Format for Bar Code Scanner LN 6L89-01 contains incorrect bar codes that can prevent the correct configuration of the bar code scanner language format. The Abbott m2000 System is intended for use in performing nucleic acid testing in clinical laboratories. It is comprised of the Ab

    • Terminated Z-0365-2012 FDA Unclassified (pre-2012) initiated 11 Oct 2011 on shared 510(k) K092705

    Abbott Molecular has received reports in which the liquid waste sensor and components in the m2000sp lower instrument cabinet overheated and/or caught fire.

    • Terminated Z-0048-2012 FDA Unclassified (pre-2012) initiated 8 Sep 2011

    The Abbott m2000rt System software has software bug which can affect customers who manually enter a Test Order onto the m2000rt and sorts a column on the calibration or control grids of the Test Order screen by double clicking the column header. This causes a mismatch between specific concentration values and the designated calibrators and controls in the final results, which could cause an inval

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K092705
  2. Recall initiated FDA recalls Z-0048-2012
  3. Recall initiated FDA recalls Z-0365-2012
  4. Recall initiated FDA recalls Z-2013-2012
  5. Recall initiated FDA recalls Z-0634-2013
  6. Recall initiated FDA recalls Z-0948-2015
  7. Recall initiated FDA recalls Z-2169-2014
  8. Recall initiated FDA recalls Z-0463-2015
  9. Listed FDA GUDID 00884999043503

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
m2000
Generic name
Laboratory analyser operation system software IVD
Model / Ref / Catalog
08N89-001
Primary DI / UDI-DI
00884999043503
510(k) Number
FDA product code
OOI
GMDN term
Laboratory analyser operation system software IVD
Device class
Class II
Regulation number
862.2570
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code OOI (real time Nucleic acid amplification system).

Other devices from Abbott Molecular

See all devices from Abbott Molecular →

Properties

  • Lot / batch number
Other properties (14, all answered No)