Skip to content

Mahurkar 8888345637

by Mozarc Medical US LLC

Ref 8888345637Model Mahurkar Acute Triple Lumen Catheters

Mahurkar 8888345637 is a triple-lumen haemodialysis catheter (EU MDD Class IIa; FDA Class II; FDA product code NIE, Catheter, Hemodialysis, Triple Lumen, Non-Implanted) made by Mozarc Medical US LLC, registered in EUDAMED on 3 Nov 2026 (Basic UDI-DI B-20884521006826), cleared under FDA 510(k) K192302 on 17 Jan 2020 (1 earlier submission) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 20884521006826), active as of 7 Nov 2026. 32 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

31 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-20884521006826 Basic UDI-DI 20884521006826UDI-DIDate3 Nov 2026RegisteredStatusActive
United StatesFDA 510(k)SEKD GUDID from GUDID Traditional NumberK192302 Date17 Jan 2020DecidedStatusActive
United StatesGUDID listing GUDID Number20884521006826 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Acute Triple Lumen Catheter Kit,Curved Extensions
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-20884521006826 registered 3 Nov 2026 Active
  • FDA 510(k) K192302 decided 17 Jan 2020 Active· +1 more in the status table
  • FDA GUDID UDI-DI 20884521006826 listed 24 Sep 2016 Listed

Recalls

32 recalls · 31 ongoing · FDA

  • 6 recalls, same reason

    • Ongoing Z-0421-2026 FDA Class II initiated 17 Oct 2025
    • Ongoing Z-0422-2026 FDA Class II initiated 17 Oct 2025
    • Ongoing Z-0423-2026 FDA Class II initiated 17 Oct 2025
    • Ongoing Z-0424-2026 FDA Class II initiated 17 Oct 2025
    • Ongoing Z-0425-2026 FDA Class II initiated 17 Oct 2025
    • Ongoing Z-0426-2026 FDA Class II initiated 17 Oct 2025

    A potential issue with the seal integrity of header bag packaging.

  • 25 recalls, same reason

    • Ongoing Z-2390-2023 FDA Class I initiated 28 Jun 2023 UDI-DI 10884521006829 listed
    • Ongoing Z-2367-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2368-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2369-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2370-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2371-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2372-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2373-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2374-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2375-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2376-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2377-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2378-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2379-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2380-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2381-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2382-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2383-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2384-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2385-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2386-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2387-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2388-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2389-2023 FDA Class I initiated 28 Jun 2023
    • Ongoing Z-2391-2023 FDA Class I initiated 28 Jun 2023

    Catheter center lumen was found to have an occlusion in the tip of the catheter; the source of the occlusion an excessive MDX, a silicone-based lubricant which coats the catheter tip. An occluded, partially or fully, and/or uncured or excessive MDX may dislodge from the catheter lead to full catheter obstruction resulting in delay to treatment and partial obstruction resulting in reduced flow, or particulate dislodgement that may result in delay to treatment, hemolysis, embolism/embolus or thrombosis/thrombus

    • Terminated Z-1955-2019 FDA Class II initiated 29 Apr 2019

    The priming volume values printed on the MAHURKA and Argyle acute catheters and Instructions for Use (IFU) are higher than the volumes required to fill each lumen.

Timeline

36 dated events

  1. Recall initiated FDA recalls Z-2388-2023
  2. Recall initiated FDA recalls Z-2389-2023
  3. Recall initiated FDA recalls Z-2391-2023
  4. Recall initiated FDA recalls Z-0421-2026
  5. Recall initiated FDA recalls Z-0422-2026
  6. Recall initiated FDA recalls Z-0423-2026
  7. Recall initiated FDA recalls Z-0424-2026
  8. Recall initiated FDA recalls Z-0425-2026
  9. Recall initiated FDA recalls Z-0426-2026
  10. Registered EUDAMED B-20884521006826

26 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
MAHURKAR™ Acute Triple Lumen Catheter Kit Curved Extension 12 Fr/Ch (4.0 mm) x 24 cm EUDAMED
Mahurkar GUDID
Generic name
Triple-lumen haemodialysis catheter
Model / reference
8888345637, Mahurkar Acute Triple Lumen Catheters
Primary DI / UDI-DI
20884521006826 EUDAMED
10884521006829 GUDID
Basic UDI-DI
B-20884521006826
510(k) Number
FDA product code
NIE
EMDN code
F900201 Temporary hemodialysis catheters and kits
GMDN term
Triple-lumen haemodialysis catheter
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
876.5540
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Size
Catheter Gauge — 12 French
Length — 24 Centimeter

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Primary DI / UDI-DIEUDAMED
20884521006826
GUDID
10884521006829
Device classEUDAMED
Class IIa
GUDID
Class II

The registries describe this device under different primary UDI-DIs (EUDAMED lists 20884521006826; FDA GUDID lists 10884521006829), so their flags are not compared. Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under TEMPORARY HEMODIALYSIS CATHETERS AND KITS.

Other devices from Mozarc Medical US LLC

See all devices from Mozarc Medical US LLC →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)