MAQUET CARDIOHELP CARDIOHELP Base Unit
Ref 701047999
MAQUET CARDIOHELP CARDIOHELP Base Unit (70104.7999) is a device classified as Class IIb in the EU and Class II in the US made by Maquet Cardiopulmonary AG, registered in EUDAMED on 11 May 2026 (Basic UDI-DI B-04037691658247), cleared under FDA 510(k) K133598 on 21 May 2014 and listed in FDA GUDID since 6 Nov 2015 (UDI-DI 04037691658247), active as of 23 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
9 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-04037691658247 04037691658247 | Date11 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04037691658247 | Date6 Nov 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK133598 | Date21 May 2014 | StatusActive |
Official records
- EUDAMED public site B-04037691658247
- AccessGUDID record 04037691658247
- FDA 510(k) database K133598
Across registries
- EUDAMED Basic UDI-DI B-04037691658247 registered 11 May 2026 Active
- FDA 510(k) K133598 decided 21 May 2014 Active
- FDA GUDID UDI-DI 04037691658247 listed 6 Nov 2015 Listed
Recalls
-
- Ongoing Z-1300-2026
Internal investigations have identified an issue with the durability of the connecting cable near the connection to the Venous Bubble Sensor. Excessive bending of the connecting cable can lead to full damage of the Venous Bubble Sensor or loose cable contact, which may trigger the errors Ven. bubble sensor defective or Ven. bubble sensor disconnected on the connected medical device. These errors can occur temporarily when the connecting cable is moved or permanently if the connection is fully compromised.
-
- Ongoing Z-1831-2024
The firm identified that the measured patient leakage current in some devices significantly exceeded expected levels.
-
- Ongoing Z-1053-2024
The Bubble Sensor optional accessory to the CARDIOHELP-i extracorporeal life support system includes an incorrect UDI Device Identifier (DI) provided with the label attached to the device.
-
- Ongoing Z-0595-2024
CARDIOHELP-i System was not properly tested to measure leakage current
-
- Ongoing Z-0605-2024
Firm received complaints of breaks in the insulation, shielding, or wires of the venous probe connection cable. Fracture of the venous probe cable may influence the management of extracorporeal support. Patient may be exposed to inappropriate blood flow, blood temperature, or hematocrit/hemoglobin levels as a result of the CARDIOHELP-i not receiving information from the venous probe.
-
- Ongoing Z-0555-2024
Certain factory settings for the device were incorrectly described in the IFU-related to the warning limits for PVen and PAux, and the default settings for the venous bubble sensor (VBS) and the automatic lock in the Minimized Extracorporeal Circulation (MECC) ThApp
-
- Ongoing Z-0290-2024
It was found that the fixation (weld) employed by the supplier of the nut bolt to the slide rail plate was insufficient. The deficient weld allows the nut bolt to break off from the slide rail plate with slight manual force.
-
- Ongoing Z-0420-2024
Product removal due to possible blocking or impairment of the CARDIOHELP Emergency Drive. This issue can lead to the patient being exposed to inappropriate low blood flow. Potential associated harms are ischemia and hypoxia.
-
- Ongoing Z-0897-2022
Potential for a loose cylindrical pin on the Transport Guard that may result in the jamming of the locking mechanism causing the Transport Guard to not open or, if the locking pin is fully disengaged from the assembly, a full disassembly of the Transport Guard may occur, resulting in a delay of support if a product exchange is necessary.
Timeline
- Recall initiated FDA recalls Z-0897-2022
- Recall initiated FDA recalls Z-0420-2024
- Recall initiated FDA recalls Z-0290-2024
- Recall initiated FDA recalls Z-0555-2024
- Recall initiated FDA recalls Z-0605-2024
- Recall initiated FDA recalls Z-0595-2024
- Recall initiated FDA recalls Z-1053-2024
- Recall initiated FDA recalls Z-1831-2024
- Recall initiated FDA recalls Z-1300-2026
- Registered EUDAMED B-04037691658247
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- CARDIOHELP Base Unit EUDAMEDMaquet Cardiohelp GUDID
- Generic name
- Cardiopulmonary bypass system, roller type
- Model / Ref / Catalog
- 701047999 EUDAMEDCARDIOHELP Base Unit GUDID70104.7999 GUDID
- Primary DI / UDI-DI
- 04037691658247
- Basic UDI-DI
- B-04037691658247
- 510(k) Number
- FDA product code
- DTQ
- EMDN code
- Z12050201 Extra-corporeal circulation systems
- GMDN term
- Cardiopulmonary bypass system, roller type
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.4220
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 701047999 | CARDIOHELP Base Unit |
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under EXTRA-CORPOREAL CIRCULATION SYSTEMS.