Skip to content

Max Vpcvariable Pitch Compression Screw 233225008

by Biomet Orthopedics, Inc.

Ref 233225008

Max Vpcvariable Pitch Compression Screw 233225008 is an orthopaedic bone screw (EU MDD Class IIb; FDA Class II; FDA product code HWC, Screw, fixation, bone) made by Biomet Orthopedics, Inc., registered in EUDAMED on 24 Oct 2026 (Basic UDI-DI B-00880304804500), cleared under FDA 510(k) K160058 on 9 Mar 2016 and listed in FDA GUDID since 30 Jun 2016 (UDI-DI 00880304804500), active as of 7 Nov 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 7 Nov 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K160058

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00880304804500 Basic UDI-DI 00880304804500UDI-DIDate24 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00880304804500 UDI-DI Date30 Jun 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK160058 Date9 Mar 2016DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00880304804500 registered 24 Oct 2026 Active
  • FDA 510(k) K160058 decided 9 Mar 2016 Active
  • FDA GUDID UDI-DI 00880304804500 listed 30 Jun 2016 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K160058
  2. Listed FDA GUDID 00880304804500
  3. Registered EUDAMED B-00880304804500

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Max Vpcvariable Pitch Compression Screw
Generic name
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Device name
Max VPC 2_5mm VPC screw
Model / Ref / Catalog
233225008
Primary DI / UDI-DI
00880304804500
Basic UDI-DI
B-00880304804500
510(k) Number
FDA product code
HWC
EMDN code
P09120602 Cancellous screws
GMDN term
Orthopaedic bone screw, non-bioabsorbable, non-sterile
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3040
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II
ImplantableEUDAMED
Yes
GUDID
No

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CANCELLOUS SCREWS.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Single use
  • Implantable YesEUDAMEDNoGUDID
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)