Skip to content

Mayfield® 422A1020

by Integra Lifesciences Corp.

Mayfield 422A1020 is a skull clamp (FDA Class II; FDA product code HBL, Holder, Head, Neurosurgical (Skull Clamp)) made by Integra Lifesciences Corp., cleared under FDA 510(k) K932807 on 28 Sep 1993 and listed in FDA GUDID since 25 Jul 2016 (UDI-DI 10381780254584), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K932807

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10381780254584 UDI-DI Date25 Jul 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK932807 Date28 Sep 1993DecidedStatusActive

Official records

From the FDA record

Device description
SLEEVE ASSEMBLY
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K932807 decided 28 Sep 1993 Active
  • FDA GUDID UDI-DI 10381780254584 listed 25 Jul 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-0548-2021 FDA Class II initiated 11 Nov 2020

    Revised Instruction Manual to reflect the most accurate illustration for Mayfield Skull Clamp A2000 Position Diagram

Timeline

3 dated events

  1. Cleared FDA 510(k) K932807
  2. Listed FDA GUDID 10381780254584
  3. Recall initiated FDA recalls Z-0548-2021

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Mayfield®
Generic name
Skull clamp
Model / reference
422A1020
Primary DI / UDI-DI
10381780254584
510(k) Number
FDA product code
HBL
GMDN term
Skull clamp
Device class
Class II
Regulation number
882.4460
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Similar devices in this category

Other devices filed under Skull clamp.

Other devices from Integra Lifesciences Corp.

See all devices from Integra Lifesciences Corp. →

Properties

  • Prescription use
  • Lot / batch number
Other properties (13, all answered No)