McCain Monopolar & Bipolar Cautery
by Walter Lorenz Surgical, Inc. 510(k)
Active
510(k) K881403
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK881403 | Date22 Jun 1988 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 22 Oct 2026.
Specification
- 510(k) Number
- FDA Product Code
- GEI
- Device Class
- Class II
- Regulation
- 21 CFR Part 878.4400
- Advisory Committee
- General, Plastic Surgery
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The McCain Monopolar & Bipolar Cautery is an electrosurgical device designed for cutting and coagulation of tissue. It operates using both monopolar and bipolar electrosurgical principles to provide precise control during surgical procedures, facilitating tissue separation and hemostasis.
This device is intended for use in surgical settings and is classified under the GEI product code for electrosurgical cutting and coagulation accessories. Supplied as a reusable instrument, it requires proper sterilization and handling per manufacturer guidelines. The device holds an FDA 510(k) clearance (K881403) under the Special Controls classification for Class II medical devices, with a clearance date of June 22, 1988.
Other devices from Walter Lorenz Surgical, Inc.
Questions
AI-generated answers, 19 Sep 2026
What types of surgical procedures is this device designed to assist with, and how does it differ between monopolar and bipolar use?
The McCain Monopolar & Bipolar Cautery is designed for cutting and coagulation of tissue during surgical procedures, offering precise control for both tissue separation and hemostasis. Monopolar cautery directs current through the patient’s body to the target tissue, ideal for larger areas or deeper cuts, while bipolar cautery confines current flow between two electrodes on the device itself, reducing risk to surrounding tissues and making it better suited for delicate or confined spaces. The device combines both modes to provide flexibility depending on the surgical need.
Is this device single-use or reusable, and what sterilization methods should be used if it’s reused?
This device is supplied as a reusable instrument, meaning it is intended to be sterilized and reused multiple times. Proper sterilization and handling per the manufacturer’s guidelines are required to maintain safety and functionality. The manufacturer’s instructions should specify approved sterilization methods, such as autoclaving or chemical sterilization, to ensure the device remains effective and free from contamination.
What regulatory pathway was followed for FDA clearance, and how does this affect its classification?
The McCain Monopolar & Bipolar Cautery received FDA clearance through a 510(k) submission (K881403), classified as Substantially Equivalent (SESE) under the Special Controls classification for Class II medical devices. This pathway was used because the device falls under the GEI product code, which categorizes electrosurgical cutting and coagulation accessories. The clearance date is June 22, 1988, and the device was reviewed by the General/Plastic Surgery (SU) Advisory Committee.
How should this device be stored to ensure it remains functional and safe for reuse?
Since this is a reusable device, it should be stored in a clean, dry environment away from direct sunlight, extreme temperatures, or sources of moisture or contamination. The manufacturer’s guidelines likely specify packaging requirements, such as using a sealed case or pouch, to protect the device from damage or degradation. Always follow the storage instructions provided to maintain sterility and operational integrity before sterilization cycles.