Medi-Ject Corporation Medi-Jector Needle-Free Bio-Tropin Ddrug Delivery Systems 0.0058/0.0068(Inch Diameter Nozzleorific
510(k) K960285
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK960285 | Date17 Apr 1996 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- KZE
- Device Class
- Class II
- Regulation
- 21 CFR Part 880.5430
- Advisory Committee
- General Hospital
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Medi-Jector Needle-Free Bio-Tropin Drug Delivery Systems are classified as non-electrically powered injectors, designed for the delivery of drugs without the use of needles. These systems utilize a high-pressure fluid jet mechanism to administer medications through the skin, leveraging a nozzle orifice with specified diameters of 0.0058 or 0.0068 inches for precise drug deposition.
Intended for use in general hospital settings, these systems are supplied as single-use devices and are regulated under FDA 510(k) clearance (K960285) as substantially equivalent to existing products. The systems are categorized under product code KZE and are designed for sterile application, adhering to regulatory standards for Class II medical devices. Storage and handling must comply with manufacturer guidelines to maintain sterility and functionality.
Other devices from Medi-Ject Corp.
Questions
AI-generated answers, 19 Sep 2026
What types of medications can the Medi-Jector Needle-Free Bio-Tropin Drug Delivery Systems administer, and how does the nozzle size factor into this?
The Medi-Jector systems are designed for delivering drugs via a high-pressure fluid jet mechanism without needles, specifically targeting applications in general hospital settings. The nozzle orifice diameters of 0.0058 inches and 0.0068 inches are engineered for precise drug deposition, ensuring controlled delivery of medications through the skin. While the exact medications aren’t specified, the nozzle size likely influences the viscosity and volume of the drug solution for optimal jet penetration and efficacy.
Are these systems reusable, or are they intended for single-use only, and how should they be stored to maintain sterility?
The Medi-Jector Needle-Free Bio-Tropin Drug Delivery Systems are explicitly supplied as single-use devices, meaning each unit is intended for one administration only. To preserve sterility and functionality, storage must follow the manufacturer’s guidelines, which likely include keeping them in sealed, sterile packaging until use and avoiding contamination or exposure to environmental conditions that could compromise integrity.
What regulatory pathway was followed for FDA clearance, and how does this classification impact its use in clinical settings?
The Medi-Jector systems received FDA 510(k) clearance (K960285) under the Traditional Review pathway, determined to be substantially equivalent to existing products. This classification places them in Class II under the FDA’s regulatory framework, requiring compliance with specific controls to ensure safety and effectiveness. Clinically, this means the device is approved for use in general hospital settings as a non-electrically powered injector, adhering to established standards for needle-free drug delivery.
What are the key differences between the two nozzle sizes (0.0058 inches vs. 0.0068 inches), and how might a clinician choose between them?
The two nozzle sizes (0.0058 inches and 0.0068 inches) likely cater to different drug formulations or patient needs, such as varying viscosity or required penetration depth. The smaller orifice (0.0058 inches) may be suited for thinner or lower-volume medications, while the larger orifice (0.0068 inches) could accommodate thicker solutions or higher delivery volumes. Clinicians would select based on manufacturer recommendations, drug specifications, and patient-specific factors like skin condition or medication properties.