Medi-Trace 1310P Combination Defibrillation, Monitoring & Pacing Electrode
510(k) K980857
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK980857 | Date12 May 1998 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- MKJ
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.5310
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Medi-Trace 1310P is a combination defibrillation, monitoring, and pacing electrode designed for use with automated external defibrillators (non-wearable). It integrates defibrillation, electrocardiogram (ECG) monitoring, and temporary cardiac pacing functions into a single electrode system, enabling comprehensive cardiac assessment and intervention during emergencies.
This device is supplied as a single-use, sterile electrode intended for pre-hospital and clinical settings. It is classified as a Class III medical device under FDA regulations (870.5310) and has received FDA 510(k) clearance (K980857) as substantially equivalent to the predicate device. Storage and handling must adhere to manufacturer guidelines to maintain sterility and functionality, ensuring readiness for immediate use in cardiac arrest or bradycardia scenarios.
Other devices from Graphic Controls Corp.
Questions
AI-generated answers, 18 Sep 2026
What types of emergencies is the Medi-Trace 1310P designed to address in pre-hospital and clinical settings?
The Medi-Trace 1310P is specifically designed for cardiac emergencies requiring defibrillation, ECG monitoring, and temporary cardiac pacing. It is intended for use during cardiac arrest scenarios or bradycardia events where immediate intervention is critical, enabling comprehensive cardiac assessment and intervention through a single electrode system.
Is the Medi-Trace 1310P reusable or intended for single-use, and how should it be stored to maintain sterility?
The Medi-Trace 1310P is a single-use, sterile electrode. To maintain sterility and functionality, storage and handling must strictly follow the manufacturer’s guidelines, ensuring it remains ready for immediate use in emergencies without compromising its sterile state.
What regulatory pathway was followed for FDA clearance of the Medi-Trace 1310P, and what classification does it hold?
The Medi-Trace 1310P underwent a traditional 510(k) clearance process and was determined to be substantially equivalent to a predicate device. It is classified as a Class III medical device under FDA regulations (870.5310), reflecting its critical role in life-saving cardiac interventions.
Can this device be used with any automated external defibrillator (non-wearable), or is it compatible only with specific models?
The Medi-Trace 1310P is designed for use with automated external defibrillators (non-wearable) in general, though compatibility should be confirmed with the specific defibrillator model in use. Its integrated design supports defibrillation, ECG monitoring, and temporary pacing, making it versatile for emergency cardiac care.