Medos Hilite Infant Oxygenator, Model 1000, 800 Lt

by Gish Biomedical, Inc.

510(k) K090449

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK090449 Date18 Sep 2009ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTZ
Device Class
Class II
Regulation
21 CFR Part 870.4350
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Medos Hilite Infant Oxygenator is a hollow fiber oxygenator designed for extracorporeal oxygenation and carbon dioxide removal from human blood during cardiopulmonary bypass procedures. Classified under product code DTZ, it is intended for neonatal and infant use, providing gas exchange in low-flow applications. The device operates within specific blood flow ranges—0.2 to 1.0 liters per minute for Model 1000 and 0.2 to 0.8 liters per minute for Model 800 LT—ensuring precise oxygenation for pediatric patients.

This device is supplied as a single-use, sterile medical product and is regulated under FDA 510(k) clearance (K090449) as a Class II device under special controls. It is intended for use in controlled clinical environments, such as operating rooms or intensive care units, where extracorporeal circulation is required. The oxygenators are not MRI-compatible and must be stored under manufacturer-recommended conditions to maintain sterility and performance. Authorized by Gish Biomedical, Inc., the device adheres to regulatory standards for cardiovascular applications.

Other devices from Gish Biomedical, Inc.

See all devices from Gish Biomedical, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Medos Hilite Infant Oxygenator 1000/800 LT used for?

    This device is designed for extracorporeal oxygenation and carbon dioxide removal during cardiopulmonary bypass procedures in neonatal and infant patients. It provides controlled gas exchange in low-flow applications, ensuring precise oxygenation for pediatric patients requiring temporary circulatory support.

  • How are the Medos Hilite Infant Oxygenator models 1000 and 800 LT different?

    The Model 1000 is optimized for blood flow rates of 0.2 to 1.0 liters per minute, while the Model 800 LT supports lower flows of 0.2 to 0.8 liters per minute. Both are intended for neonatal and infant use but differ in their maximum blood flow capacity to match specific clinical needs.

  • Is the Medos Hilite Infant Oxygenator single-use or reusable?

    The device is supplied as a single-use, sterile product. This ensures patient safety by eliminating the risk of cross-contamination between uses, adhering to best practices for sterile medical devices in controlled clinical environments.

  • What storage conditions are required to maintain sterility and performance?

    The device must be stored under manufacturer-recommended conditions to preserve sterility and functionality. Proper storage prevents degradation and ensures the oxygenator remains effective for its intended use in operating rooms or intensive care units.

  • Can the Medos Hilite Infant Oxygenator be used in MRI environments?

    No, the device is explicitly not MRI-compatible. It should only be used in non-MRI settings to avoid interference or safety risks associated with magnetic fields.