Skip to content

Medpor Titan 81022

by Stryker Leibinger

Ref 81022

Medpor Titan 81022 is a medical device (EU MDD Class IIb; FDA Class II; FDA product code FTM, Mesh, surgical; EMDN category non-resorbable filling and reconstruction devices) made by Stryker Leibinger, registered in EUDAMED on 5 Nov 2026 (Basic UDI-DI B-07613252084235), cleared under FDA 510(k) K040364 on 30 Jun 2004 and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 07613252084235), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K040364

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-07613252084235 Basic UDI-DI 07613252084235UDI-DIDate5 Nov 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number07613252084235 UDI-DI Date24 Sep 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK040364 Date30 Jun 2004DecidedStatusActive

Official records

From the FDA record

Device description
MEDPOR TITAN MEDPOR (MTM)
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-07613252084235 registered 5 Nov 2026 Active
  • FDA 510(k) K040364 decided 30 Jun 2004 Active
  • FDA GUDID UDI-DI 07613252084235 listed 24 Sep 2015 Listed

Recalls

3 recalls · FDA

    • Terminated Z-0715-2022 FDA Class II initiated 29 Dec 2021

    Inside the packaging of one reported item a non-conforming product was found. Contrary to the design, the barrier layer was manufactured on the inferior side of the implant versus the superior side.

    • Terminated Z-1093-2015 FDA Class II initiated 17 Dec 2014 on shared 510(k) K040364

    Article #81036 (MEDPOR Titan Max OFW - MTB - Right) reportedly contained article #81035 MEDPOR Titan Max OFW - MTB - Left. The appropriate articles were actually included in the shipment. However, the products had an incorrect barrier location.

    • Terminated Z-0922-2012 FDA Unclassified (pre-2012) initiated 16 Dec 2011

    The template that is packaged with this implant was not packaged according to specification. The template was packaged in a single pouch instead of a double pouch.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K040364
  2. Recall initiated FDA recalls Z-0922-2012
  3. Recall initiated FDA recalls Z-1093-2015
  4. Listed FDA GUDID 07613252084235
  5. Recall initiated FDA recalls Z-0715-2022
  6. Registered EUDAMED B-07613252084235

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Medpor Titan
Generic name
Polyethylene craniofacial tissue reconstructive material
Model / Ref / Catalog
81022
Primary DI / UDI-DI
07613252084235
Basic UDI-DI
B-07613252084235
510(k) Number
FDA product code
FTM
EMDN code
P900403 Non-resorbable filling and reconstruction devices
GMDN term
Polyethylene craniofacial tissue reconstructive material
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
878.3300
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution
Size
Width — 50.0 Millimeter
Length — 38.0 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under NON-RESORBABLE FILLING AND RECONSTRUCTION DEVICES.

Other devices from Stryker Leibinger

  • 92-55772

    Class II
  • 92-55773

    Class II
  • 92-55771

    Class II
  • 92-55770

    Class II

See all devices from Stryker Leibinger →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (18, all answered No)