Medtronic 6957 Permanent Pacemaker Electrode
510(k) K843706
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK843706 | Date27 Dec 1984 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Medtronic 6957
- 510(k) Number
- FDA product code
- DTB
- Device class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory committee
- Cardiovascular
- FDA decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Medtronic 6957 is a Permanent Pacemaker Electrode, classified under product code DTB. This unipolar screw-in lead is designed for implantation in cardiac pacing applications, providing electrical stimulation to regulate heart rhythm in patients requiring chronic pacing support.
This device is intended for single-use implantation in sterile operating room settings, adhering to Class III regulatory standards. Supplied sterile and packaged for surgical use, it requires professional medical expertise for positioning within the heart’s right ventricle or atrium. Authorized under FDA 510(k) clearance (K843706), it is not MRI-compatible and must be handled with care to avoid damage. Storage follows manufacturer guidelines to maintain sterility and functionality.
Other devices from Medtronic Vascular, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the intended use of the Medtronic 6957?
The Medtronic 6957 is a permanent pacemaker electrode designed for cardiac pacing applications. It is a unipolar screw-in lead intended to provide electrical stimulation to regulate heart rhythm in patients who require chronic pacing support. It must be positioned within the patient's right ventricle or atrium by a medical professional.
Is the Medtronic 6957 suitable for reuse or MRI procedures?
No, the device is strictly for single-use implantation and is not MRI-compatible. Because it is supplied sterile for surgical use, it must not be reused to ensure patient safety and maintain the integrity of the device. Additionally, the device is not compatible with MRI environments, so clinicians must avoid exposing the implanted lead to MRI procedures.
How is the Medtronic 6957 supplied and what are the storage requirements?
The device is supplied sterile and packaged specifically for surgical use in a sterile operating room setting. To maintain its sterility and functionality, the device must be stored according to the manufacturer's guidelines. Proper storage is essential to ensure the lead remains safe and effective for its intended implantation procedure.
What is the regulatory status of the Medtronic 6957?
The Medtronic 6957 is authorized under FDA 510(k) clearance, specifically identified by K-number K843706. It is classified as a Class III device under regulation number 870.3680. This clearance indicates that the device was reviewed and found to be substantially equivalent to existing devices for its intended use.