Mersilene RS21
by Ethicon Inc.
Ref RS21
Mersilene RS21 is a polyester suture (EU MDD Class IIb; FDA Class II; FDA product code GAT, Suture, Nonabsorbable, Synthetic, Polyethylene) made by Ethicon Inc., registered in EUDAMED on 15 Sep 2026 (Basic UDI-DI B-USMF000013112000195L3), cleared under FDA 510(k) K946173 on 9 Jan 1995 and listed in FDA GUDID since 1 Sep 2015 (UDI-DI D-USMF000013112000195L3), active as of 25 Oct 2026.
Active
Valid until
No date given
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-USMF000013112000195L3 D-USMF000013112000195L3 | Date15 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | NumberD-USMF000013112000195L3 | Date1 Sep 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK946173 | Date9 Jan 1995 | StatusActive |
Official records
- EUDAMED public site B-USMF000013112000195L3
- AccessGUDID record 10705031049789
- FDA 510(k) database K946173
From the FDA record
- Device description
- White Woven Polyester Fiber, Nonabsorbable Surgical Ligature
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-USMF000013112000195L3 registered 15 Sep 2026 Active
- FDA 510(k) K946173 decided 9 Jan 1995 Active
- FDA GUDID UDI-DI D-USMF000013112000195L3 listed 1 Sep 2015 Listed
Recalls
-
- Ongoing Z-0284-2027
Nylon suture indicated for use in general soft tissue approximation and/or ligation may have needles with distorted curvature, that may break during use, or could cause additional soft tissue or vessel injury, including tearing or bleeding intraoperatively.
-
- Ongoing Z-0153-2027
Silk sutures, indicated for use in cardiovascular, ophthalmic and neurological procedures, packaged with alcohol-based fluid, not part of product design, that if discovered prior to use may cause surgical delay. If used, fluid could cause reduced suture tensile strength or knot security, tissue irritation/inflammatory tissue response, and treatment failure, including wound dehiscence/bleeding.
-
- Ongoing Z-1516-2025
Identified curing issues with the silicone during the needles manufacturing process.
-
- Ongoing Z-1097-2025
Sutures may have an open seal on the primary packaging, due to a manufacturing issue on a specific machine, and if issue is undetected could lead to breach in sterility, could introduce pathogens to the patient and cause infection.
-
- Ongoing Z-2486-2020
Lots of size 8-0 Blue twisted Silk Suture may not meet the stringent full shelf life of 5 years
-
- Terminated Z-1841-2019
- Terminated Z-1842-2019
Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot
-
- Terminated Z-0747-2019
The sutures inside the packaging are not the same size or type as indicated on the label.
-
- Terminated Z-1839-2015
Ethicon Fast Absorbing Surgical Gut (Plain) Suture is being recalled because the labeling on the box and foil are incomplete.
-
- Terminated Z-0492-2015
Ethicon is unable to ensure that PERMA-HAND silk suture (siliconized black braid) meets the expected sterility assurance level for sterile products.
Timeline
- Listed FDA GUDID D-USMF000013112000195L3
- Recall initiated FDA recalls Z-0747-2019
- Recall initiated FDA recalls Z-1841-2019
- Recall initiated FDA recalls Z-1842-2019
- Recall initiated FDA recalls Z-2486-2020
- Recall initiated FDA recalls Z-1097-2025
- Recall initiated FDA recalls Z-1516-2025
- Recall initiated FDA recalls Z-0153-2027
- Registered EUDAMED B-USMF000013112000195L3
- Recall initiated FDA recalls Z-0284-2027
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Mersilene
- Generic name
- Polyester suture, non-bioabsorbable, multifilament, non-antimicrobial
- Model / Ref / Catalog
- RS21
- Primary DI / UDI-DI
- D-USMF000013112000195L3 EUDAMED10705031049789 GUDID
- Basic UDI-DI
- B-USMF000013112000195L3
- 510(k) Number
- FDA product code
- GAT
- EMDN code
- H90020102 Cerclage tapes
- GMDN term
- Polyester suture, non-bioabsorbable, multifilament, non-antimicrobial
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 878.5000
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Belgium
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Primary DI / UDI-DI | D-USMF000013112000195L3 | 10705031049789 |
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under TAPES, MEDICAL/SURGICAL.
- Luxor 813-3 by LUXOR SAĞLIK ÜRÜNLERİ SAN. VE TİC. A.Ş.
- KALFF W810U9878 by Ningbo Chinmed Technology Co., Ltd.
- Medical adhesive tape HF-38/10-SHP by JIAXING HOW SPORT MEDICAL INSTRUMENT CO., LTD.
- Elastic adhesive bandage EW-100/4.5-HGM(F) by JIAXING HOW SPORT MEDICAL INSTRUMENT CO., LTD.
- Silk Tape rule1 by Nanjing 3H Medical Products Co., Ltd.
- paper tape PM11032 by Ningbo Pinmed Instruments Co., Ltd.
- PointGuards 318 by Beekley Corporation
- ILLUMISITE ILS-1000-SP by Covidien LP
- Medical Tape Silk tape by Anji Xinyuan Medical Supplies Co.,Ltd.
- Swift Loop 1010643 by Coroneo Inc