← Back to catalogue
METICULY Patient-specific titanium maxillofacial mesh implant
FDA UDIClass II (US FDA UDI)
Identity
- Trade Name
- METICULY Patient-specific titanium maxillofacial mesh implant FDA UDI
- Generic Name
- Craniofacial fixation plate, non-bioabsorbable, non-customized FDA UDI
- Device Name
- The METICULY Patient-specific titanium maxillofacial mesh implant is a device designed individually for each patient and intended for use in selective trauma of the maxillofacial skeleton, maxillofacial surgery, and reconstructive procedures. It is specifically designed with a focus on applications of non-bending related scenarios. The implant is made of titanium alloys produced via additive manufacturing (Laser Powder Bed Fusion) and is intended to be used with titanium screws. All additive manufacturing and other post processing steps are only to take place under Meticuly manufacturing control. The device is not intended to substitute for bone reconstruction in clinical situations where bone is needed for support and stability of the maxillofacial skeleton under functional loading conditions. It is intended for adults only (at least 22 years of age). The surgeon approves the design of the mesh implant prior to fabrication of the implant device by the sponsor. The proposed FaciMesh models are intended to treat the maxillofacial region, while the OrbiMesh models treat the Orbital region. The device is not intended for reconstruction of the orbital roof defects or for any frontal bone defects, such as the supra-orbital ridge. Additionally, the FDA-cleared commercially available titanium screws that can be used with the subject devices include the TITANIUM MINIPLATE SYSTEM (K951690) and MICRO TITANIUM PLATE SYSTEM (K951688). FDA UDI
- Model / Reference
- MF-312 FDA UDI
- Description
- The METICULY Patient-specific titanium maxillofacial mesh implant is a device designed individually for each patient and intended for use in selective trauma of the maxillofacial skeleton, maxillofacial surgery, and reconstructive procedures. It is specifically designed with a focus on applications of non-bending related scenarios. The implant is made of titanium alloys produced via additive manufacturing (Laser Powder Bed Fusion) and is intended to be used with titanium screws. All additive manufacturing and other post processing steps are only to take place under Meticuly manufacturing control. The device is not intended to substitute for bone reconstruction in clinical situations where bone is needed for support and stability of the maxillofacial skeleton under functional loading conditions. It is intended for adults only (at least 22 years of age). The surgeon approves the design of the mesh implant prior to fabrication of the implant device by the sponsor. The proposed FaciMesh models are intended to treat the maxillofacial region, while the OrbiMesh models treat the Orbital region. The device is not intended for reconstruction of the orbital roof defects or for any frontal bone defects, such as the supra-orbital ridge. Additionally, the FDA-cleared commercially available titanium screws that can be used with the subject devices include the TITANIUM MINIPLATE SYSTEM (K951690) and MICRO TITANIUM PLATE SYSTEM (K951688). FDA UDI
Identifiers
- Primary DI / UDI-DI
- 08859751213120 FDA UDI
- 510(k) Number
- K232889 FDA UDI
- FDA Product Code
- JEY FDA UDI
- GMDN Term
- Craniofacial fixation plate, non-bioabsorbable, non-customized FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 872.4760 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
Yes
FDA UDI
Implantable
Yes
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
Yes
FDA UDI
Moist Heat or Steam Sterilization FDA UDI
MR Unsafe FDA UDI
Category: Craniofacial fixation plate, non-bioabsorbable, non-customized
METICULY Patient-specific titanium maxillofacial mesh implant by Meticuly Co., Ltd. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Craniofacial fixation plate, non-bioabsorbable, non-customized.
- LEVEL ONE CMF — KLS-Martin L.P. · Class II
- Leforte System Bone Plate — Jeil Medical Corporation · Class II
- CMF VISIONARE — VISIONARE LLC · Class II
- MCI - Medical Concept Innovation, Inc. — MCI MEDICAL CONCEPT INNOVATION INC. · Class II
- TraumaOne SYSTEM — BIOMET MICROFIXATION, INC · Class II
- Leforte System Bone Plate — Jeil Medical Corporation · Class II
- AccuPlate® Patient-Specific Plate — Medcad · Class II
- Leforte Neuro System Bone Plate — Jeil Medical Corporation · Class II
Cleared under the same submission
K232889 also covers:
- METICULY Patient-specific titanium maxillofacial mesh implant — Meticuly Co., Ltd.
- METICULY Patient-specific titanium maxillofacial mesh implant — Meticuly Co., Ltd.
- METICULY Patient-specific titanium maxillofacial mesh implant — Meticuly Co., Ltd.
- METICULY Patient-specific titanium maxillofacial mesh implant — Meticuly Co., Ltd.
- METICULY Patient-specific titanium maxillofacial mesh implant — Meticuly Co., Ltd.
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Meticuly Co., Ltd.
Sources (1)
- FDA UDI 4f1e5915-691d-4496-9d33-890bcbc73f2d 34 fields · synced Jun 8, 2026