# Micra™ AV2 MC2AVR1

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/micra-av2-mc2avr1>
- Manufacturer: [Medtronic, Inc.](https://devicerts.com/manufacturers/medtronic-inc) (United States)
- Device class: Class III (US FDA)
- FDA product code: PNJ
- GMDN: Intracardiac pacemaker (60789)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 00763000078645 · listed 2023-05-05 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA PMA · United States · P150033 · decision 2016-04-06 · decision APPR · status: Active · from GUDID

## Recalls

- Z-2128-2025 · Class II · ongoing · initiated 2025-06-17 · matched through shared submission P150033, may concern other models: A software update for Medtronic CareLink SmartSync Device Manager (SmartSync) is now available. The update eliminates the potential display of an erroneous electrical reset (pop-up) message upon interrogation with a SmartSync Device Manager. The erroneous message indicates an electrical reset has occurred. However, no reset has actually occurred and there are no parameter changes or loss of diagnostics. Prior to this software update, if an erroneous SmartSync message was displayed, confusion regarding the message could have caused a clinician to consider an unnecessary system revision. Medtronic has received 39 reports of this display error with two instances of unnecessary device explant through 30 April 2025.
- Z-2127-2025 · Class II · ongoing · initiated 2025-06-17 · matched through shared submission P150033, may concern other models: A software update for Medtronic CareLink SmartSync Device Manager (SmartSync) is now available. The update eliminates the potential display of an erroneous electrical reset (pop-up) message upon interrogation with a SmartSync Device Manager. The erroneous message indicates an electrical reset has occurred. However, no reset has actually occurred and there are no parameter changes or loss of diagnostics. Prior to this software update, if an erroneous SmartSync message was displayed, confusion regarding the message could have caused a clinician to consider an unnecessary system revision. Medtronic has received 39 reports of this display error with two instances of unnecessary device explant through 30 April 2025.
- Z-2492-2019 · Class II · terminated · initiated 2019-08-06: Medtronic is updating the Micra Instructions for Use (IFU) and the Micra Implant Procedure Tip Card to include specific information on the removal of the tether to release the Micra Pacemaker from the Micra Delivery System during implant.
- Z-2493-2019 · Class II · terminated · initiated 2019-08-06: Medtronic is updating the Micra Instructions for Use (IFU) and the Micra Implant Procedure Tip Card to include specific information on the removal of the tether to release the Micra Pacemaker from the Micra Delivery System during implant.

## Identity

- Trade name: Micra™ AV2 [FDA GUDID (AccessGUDID)]
- Generic name: Intracardiac pacemaker [FDA GUDID (AccessGUDID)]
- Model / reference: MC2AVR1 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00763000078645 [FDA GUDID (AccessGUDID)]
- PMA number: P150033 [FDA GUDID (AccessGUDID)]
- FDA product code: PNJ [FDA GUDID (AccessGUDID)]
- GMDN term: Intracardiac pacemaker (60789) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class III [FDA GUDID (AccessGUDID)]
- Regulation number: 870.3610 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- MRI safety: MR Conditional [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Catheter Working Length — 105.0 Centimeter [FDA GUDID (AccessGUDID)]; Catheter Gauge — 23.0 French [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Implantable: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Combination product: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Micra™ AV2 MC2AVR1, Medtronic, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/micra-av2-mc2avr1 (data as of 2026-11-21).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-21
- JSON: <https://devicerts.com/devices/micra-av2-mc2avr1.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/micra-av2-mc2avr1
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.