Micro-Struc Acetabular Component MC2P
510(k) K850352
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK850352 | Date25 Apr 1985 | StatusActive |
Recalls
-
- Ongoing Z-3196-2026
Affected devices were manufactured with Ultra High Molecular Weight Polyethylene (UHMWPE) raw material aged in excess of five years. Product has the potential for elevated levels of oxidation, which may result in increased wear, leading to hazards such as excessive wear debris, material fragments, fractured device, or disassociated device. Potential harms include revision surgery, pain, and inflammation.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Micro-Struc. Acetabular Compon- MC2P
- 510(k) Number
- FDA Product Code
- JDL
- Device Class
- Class III
- Regulation
- 21 CFR Part 888.3320
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Micro-Struc Acetabular Component MC2P is a Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component). This device is designed to replace the damaged or diseased acetabulum in total hip arthroplasty, providing a stable, metal-backed bearing surface for articulation with a femoral component. Its semi-constrained design offers enhanced stability while maintaining mobility, making it suitable for patients requiring hip joint reconstruction.
The MC2P is supplied as a reusable, metal acetabular component intended for cemented fixation within the pelvis. It is classified as a Class III device under FDA regulations and has received FDA 510(k) clearance (K850352, K900438) via the Traditional pathway. The component is engineered for use in orthopedic surgical settings and adheres to regulatory standards for hip prostheses, including specific product codes (JDL, JDI) and manufacturing compliance under 21 CFR 888.3320. No additional sterility or MRI safety specifications are noted in the available data.
Other devices from Osteonics Corp.
Questions
AI-generated answers, 18 Sep 2026
What types of patients is the Micro-Struc Acetabular Component MC2P designed for, and how does its semi-constrained design benefit them?
The Micro-Struc Acetabular Component MC2P is designed for patients undergoing total hip arthroplasty who require replacement of a damaged or diseased acetabulum. Its semi-constrained design provides enhanced stability while preserving mobility, making it particularly suitable for patients who need a balance between joint stability and range of motion during reconstruction.
Is the Micro-Struc Acetabular Component MC2P intended for single-use or reusable applications, and how should it be fixed in place?
The Micro-Struc Acetabular Component MC2P is explicitly designed as a reusable device. It is intended for cemented fixation within the pelvis, meaning it is secured in place using bone cement during orthopedic surgery.
What regulatory pathway was followed for FDA clearance of this device, and what does that mean for its use in clinical settings?
The Micro-Struc Acetabular Component MC2P received FDA 510(k) clearance through the Traditional pathway, which means it was determined to be substantially equivalent to a legally marketed predicate device. This clearance allows it to be used in clinical settings for its intended purpose—replacing the acetabulum in total hip arthroplasty—while adhering to FDA Class III regulatory standards for hip prostheses.
Are there specific sizes or models available for the Micro-Struc Acetabular Component MC2P, and how would a clinician determine the correct fit for a patient?
While the exact sizes or model variants are not detailed in the provided data, the device is categorized under product code JDL and is engineered for orthopedic use in acetabular replacement. Clinicians would typically select the appropriate size based on preoperative imaging (e.g., CT or X-ray) and surgical assessment of the patient’s pelvic anatomy to ensure proper fit and function during total hip arthroplasty.
Does the Micro-Struc Acetabular Component MC2P require any special handling or storage conditions, such as sterility or environmental precautions?
The available data does not specify any special sterility requirements or MRI safety considerations for the Micro-Struc Acetabular Component MC2P. However, as a reusable metal acetabular component intended for surgical use, it should be handled according to standard orthopedic surgical protocols, including proper cleaning, sterilization (if reused), and storage in a clean, dry environment to maintain its integrity before and after use.