# Microtargeting Drive System

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/microtargeting-drive-system-haw>
- Manufacturer: [Fhc, Inc.](https://devicerts.com/manufacturers/fhc-inc) (United States)
- Name in the registry: MICROTARGETING DRIVE SYSTEM
- Device class: Class II (US FDA)
- FDA product code: HAW

## Overview

*AI-generated summary, 2026-09-19. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Microtargeting Drive System is a neurosurgical device classified as a stereotactic drive mechanism (Product Code HAW), designed for precise advancement and retraction of microelectrodes, stimulation electrodes, or other instruments within the brain or nervous system. It provides controlled, incremental movement to facilitate accurate neurosurgical procedures, including deep brain stimulation (DBS) and electrode placement.

This system is supplied as a reusable, non-sterile device intended for use in operating rooms or neurosurgical suites. It requires sterilisation prior to each use and is compatible with leading stereotactic systems via optional frame adapters. The device holds FDA 510(k) clearance (K003776) under the Traditional review pathway, with a decision date of February 23, 2001, and is distributed by FHC, Inc. (Bowdoinham, ME, USA).

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K003776 · decision 2001-02-23 · decision SESE · status: Active

## Recalls

- Z-0311-2011 ·  · terminated · initiated 2010-03-30: Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.
- Z-0313-2011 ·  · terminated · initiated 2010-03-30: Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.
- Z-0314-2011 ·  · terminated · initiated 2010-03-30: Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.
- Z-0895-05 ·  · terminated · initiated 2005-03-14: Potential for non-sterile pin to contaminate sterile field

## Identifiers

- 510(k) Number: K003776 [FDA 510(k)]
- FDA product code: HAW [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 882.4560 [FDA 510(k)]
- Advisory committee: Neurology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: Microtargeting Drive System, Fhc, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/microtargeting-drive-system-haw (data as of 2026-11-24).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/microtargeting-drive-system-haw.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/microtargeting-drive-system-haw
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.