Skip to content

Microtek 1

by Microtek Medical LLC 1,000+ variants

Microtek 1 is a body-orifice ultrasound imaging transducer cover (FDA Class II; FDA product code IYO, System, imaging, pulsed echo, ultrasonic) made by Microtek Medical LLC, cleared under FDA 510(k) K961029 on 25 Jul 1996 and listed in FDA GUDID since 30 Jan 2017 (UDI-DI 00748426054008), active as of 23 Oct 2026. 2 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

510(k) K961029

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00748426054008 UDI-DI Date30 Jan 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK961029 Date25 Jul 1996DecidedStatusActive

Official records

From the FDA record

Device description
PROBE COVER, ROLLED
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as containing natural rubber latex
Sterility
Supplied sterile; sterilise before use (Radiation Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K961029 decided 25 Jul 1996 Active
  • FDA GUDID UDI-DI 00748426054008 listed 30 Jan 2017 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-2333-2018 FDA Class III initiated 22 Nov 2017
    • Terminated Z-2332-2018 FDA Class III initiated 22 Nov 2017

    The incorrect IFU was shipped with the product.

Timeline

4 dated events

  1. Cleared FDA 510(k) K961029
  2. Listed FDA GUDID 00748426054008
  3. Recall initiated FDA recalls Z-2333-2018
  4. Recall initiated FDA recalls Z-2332-2018

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Microtek
Generic name
Body-orifice ultrasound imaging transducer cover, basic
Model / reference
1
Primary DI / UDI-DI
00748426054008
510(k) Number
FDA product code
IYO
GMDN term
Body-orifice ultrasound imaging transducer cover, basic
Device class
Class II
Regulation number
892.1560
GUDID distribution status
In Commercial Distribution
Sterilisation method
Radiation Sterilization

Similar devices in this category

Other devices filed under Body-orifice ultrasound imaging transducer cover, basic.

Other devices from Microtek Medical LLC

See all devices from Microtek Medical LLC →

Properties

  • Supplied sterile
  • Sterilise before use
  • Single use
  • Contains latex
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)