Skip to content

Microtest M4RT (3ml) W/O Beads NP Swab Kit PK/ 100

by Remel, Inc.

Part of a family of 8 devices: see the family page

Ref R12705

Microtest M4RT (3ml) W/O Beads NP Swab Kit PK/ 100 (R12705) is a microbiological transport medium IVD (EU IVDR Class A) made by Remel, Inc., registered in EUDAMED on 2 Apr 2026 (Basic UDI-DI 8488380M4RTKitEB), cleared under FDA 510(k) K965152 on 22 Jan 1997 and listed in FDA GUDID since 22 Dec 2022 (UDI-DI 00842558109527), active as of 22 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K965152

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number8488380M4RTKitEB Basic UDI-DI 00842558109527UDI-DIDate2 Apr 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00842558109527 UDI-DI Date22 Dec 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK965152 Date22 Jan 1997DecidedStatusActive

Official records

From the FDA record

Device description
M4RT(3ml) w/o BEADS NP Swab Kit 100/pk
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8488380M4RTKitEB registered 2 Apr 2026 Active
  • FDA 510(k) K965152 decided 22 Jan 1997 Active
  • FDA GUDID UDI-DI 00842558109527 listed 22 Dec 2022 Listed

Recalls

1 recall · FDA

    • Terminated Z-1139-2010 FDA Unclassified (pre-2012) initiated 18 Jan 2010 on shared 510(k) K965152

    Pouch may be inadequately heat sealed compromising sterility

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K965152
  2. Recall initiated FDA recalls Z-1139-2010
  3. Listed FDA GUDID 00842558109527
  4. Registered EUDAMED 8488380M4RTKitEB

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Microtest M4RT (3ml) W/O Beads Np Swab Kit Pk/ 100 EUDAMED
MicroTest M4RT GUDID
Generic name
Microbiological transport medium IVD
Device name
Microtest M4RT Kit
Model / Ref / Catalog
R12705
Primary DI / UDI-DI
00842558109527
Basic UDI-DI
8488380M4RTKitEB
510(k) Number
EMDN code
W0104010203 Transport media
GMDN term
Microbiological transport medium IVD
Device class
Class A
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Manufacturer details

EUDAMED SRN
US-MF-000044686
Authorised representative
Thermo Fisher Diagnostics B.V. NL-AR-000013157

Similar devices in this category

Other devices filed under TRANSPORT MEDIA.

Other devices from Remel, Inc.

See all devices from Remel, Inc. →

Properties

  • Contains animal tissues or cells
  • Reagent
  • IVD kit
  • Professional testing
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (19, all answered No)