Skip to content

Midas Rex Legend 15MH30SH

by Medtronic Powered Surgical Solutions

Ref 15MH30SH

Midas Rex Legend 15MH30SH is a device classified as Class IIa in the EU and Class II in the US made by Medtronic Powered Surgical Solutions, registered in EUDAMED on 28 Oct 2026 (Basic UDI-DI 0763000B00014197W), cleared under FDA 510(k) K170312 on 15 May 2017 (1 earlier submission) and listed in FDA GUDID since 12 Mar 2022 (UDI-DI 00763000453589), active as of 7 Nov 2026. 8 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

9 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B00014197W Basic UDI-DI 00763000453589UDI-DIDate28 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00763000453589 UDI-DI Date12 Mar 2022ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK170312 Date15 May 2017DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0763000B00014197W registered 28 Oct 2026 Active
  • FDA 510(k) K170312 decided 15 May 2017 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00763000453589 listed 12 Mar 2022 Listed

Recalls

9 recalls · FDA

    • Terminated Z-1602-2016 FDA Class II initiated 8 Apr 2016

    Incorrect color coding and attachment reference were included on the labeling of 10BA40D dissecting tools with lot number H5237248.

    • Terminated Z-0321-2016 FDA Class II initiated 21 Oct 2015

    The wire pass hole is not present on the tools.

    • Terminated Z-0546-2010 FDA Unclassified (pre-2012) initiated 30 Nov 2009

    Component of product attachment may be outside established tolerance with potential for footed portion to break during normal use.

    • Terminated Z-2156-2008 FDA Unclassified (pre-2012) initiated 30 May 2008

    Cutting flute geometry of surgical dissecting tools may be outside of established tolerance. This may lead to reduced cutting performance, inability to perform desired dissection, increased risk of overheating, and potential need for revision surgery.

    • Terminated Z-1574-05 FDA Unclassified (pre-2012) initiated 1 Sep 2005 on shared 510(k) K020069

    Potential compromise of sterile packaging for disposable dissecting tools.

    • Terminated Z-1067-05 FDA Unclassified (pre-2012) initiated 29 Jun 2005

    Complaints of finger control component breaking off and falling into open surgical wound.

    • Terminated Z-0278-05 FDA Unclassified (pre-2012) initiated 11 Nov 2004

    Softer hose increases the propensity for outer exhaust hose to kink or become occluded as a result of clamping. Complaints of hose rupture/burst have been reported.

    • Terminated Z-0213-05 FDA Unclassified (pre-2012) initiated 3 Nov 2004

    Reduced plastic thickness of lubricant/diffuser cartidge can crack under pressure causing leakage of lubricant as visible mist (appearance of smoke).

    • Terminated Z-0419-03 FDA Unclassified (pre-2012) initiated 11 Nov 2002

    Lubricant leaking from motor after sterilization causing bleed-through sterilization wrap and/or excess lubricant in instrument case.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Recall initiated FDA recalls Z-0278-05
  2. Recall initiated FDA recalls Z-1067-05
  3. Recall initiated FDA recalls Z-1574-05
  4. Recall initiated FDA recalls Z-2156-2008
  5. Recall initiated FDA recalls Z-0546-2010
  6. Recall initiated FDA recalls Z-0321-2016
  7. Recall initiated FDA recalls Z-1602-2016
  8. Cleared FDA 510(k) K170312
  9. Listed FDA GUDID 00763000453589
  10. Registered EUDAMED 0763000B00014197W

3 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Midas Rex Legend
Generic name
Orthopaedic bur, single-use
Device name
Midas Rex™ Legend
Model / reference
15MH30SH
Primary DI / UDI-DI
00763000453589
Basic UDI-DI
0763000B00014197W
510(k) Number
FDA product code
HBB
EMDN code
Z12100985 Instruments for motorised neurosurgery systems - consumables
GMDN term
Orthopaedic bur, single-use
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
882.4370
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Other devices from Medtronic Powered Surgical Solutions

See all devices from Medtronic Powered Surgical Solutions →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)