Midas Rex Legend AC16
by Medtronic Powered Surgical Solutions
Ref AC16
Midas Rex Legend AC16 is a device classified as Class IIa in the EU and Class II in the US made by Medtronic Powered Surgical Solutions, registered in EUDAMED on 26 Oct 2026 (Basic UDI-DI 0763000B00013357P), cleared under FDA 510(k) K170312 on 15 May 2017 (1 earlier submission) and listed in FDA GUDID since 23 Dec 2021 (UDI-DI 00763000440329), active as of 7 Nov 2026. 8 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0763000B00013357P 00763000440329 | Date26 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00763000440329 | Date23 Dec 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK170312 | Date15 May 2017 | StatusActive |
Official records
- EUDAMED public site 0763000B00013357P
- AccessGUDID record 00763000440329
- FDA 510(k) database K170312
- FDA 510(k) database K020069
Across registries
- EUDAMED Basic UDI-DI 0763000B00013357P registered 26 Oct 2026 Active
- FDA 510(k) K170312 decided 15 May 2017 Active
- FDA GUDID UDI-DI 00763000440329 listed 23 Dec 2021 Listed
Recalls
-
- Terminated Z-1602-2016
Incorrect color coding and attachment reference were included on the labeling of 10BA40D dissecting tools with lot number H5237248.
-
- Terminated Z-0321-2016
The wire pass hole is not present on the tools.
-
- Terminated Z-0546-2010
Component of product attachment may be outside established tolerance with potential for footed portion to break during normal use.
-
- Terminated Z-2156-2008
Cutting flute geometry of surgical dissecting tools may be outside of established tolerance. This may lead to reduced cutting performance, inability to perform desired dissection, increased risk of overheating, and potential need for revision surgery.
-
- Terminated Z-1574-05
Potential compromise of sterile packaging for disposable dissecting tools.
-
- Terminated Z-1067-05
Complaints of finger control component breaking off and falling into open surgical wound.
-
- Terminated Z-0278-05
Softer hose increases the propensity for outer exhaust hose to kink or become occluded as a result of clamping. Complaints of hose rupture/burst have been reported.
-
- Terminated Z-0213-05
Reduced plastic thickness of lubricant/diffuser cartidge can crack under pressure causing leakage of lubricant as visible mist (appearance of smoke).
-
- Terminated Z-0419-03
Lubricant leaking from motor after sterilization causing bleed-through sterilization wrap and/or excess lubricant in instrument case.
Timeline
- Recall initiated FDA recalls Z-0278-05
- Recall initiated FDA recalls Z-1067-05
- Recall initiated FDA recalls Z-1574-05
- Recall initiated FDA recalls Z-2156-2008
- Recall initiated FDA recalls Z-0546-2010
- Recall initiated FDA recalls Z-0321-2016
- Recall initiated FDA recalls Z-1602-2016
- Cleared FDA 510(k) K170312
- Listed FDA GUDID 00763000440329
- Registered EUDAMED 0763000B00013357P
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Midas Rex Legend
- Generic name
- Burring power tool attachment
- Device name
- Legend Contra-Angled Attachment
- Model / reference
- AC16
- Primary DI / UDI-DI
- 00763000440329
- Basic UDI-DI
- 0763000B00013357P
- FDA product code
- HBB
- EMDN code
- Z12100980 Instruments for motorised neurosurgery systems - hardware accessories
- GMDN term
- Burring power tool attachment
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 882.4370
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Ethylene Oxide
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under INSTRUMENTS FOR MOTORISED NEUROSURGERY SYSTEMS - HARDWARE ACCESSORIES.
- AESCULAP GC919R by AESCULAP, INC.
- ELAN 4 GA822 by Aesculap AG
- Aesculap GC921R by Aesculap AG
- Foot control pedals used in combination with surgical power tools to ream, bur, drill and cut bone MFP-121 by Zethon Ltd
- AESCULAP GC654R by AESCULAP, INC.
- Foot control pedals used in combination with surgical power tools to ream, bur, drill and cut bone MFP-120 by Zethon Ltd