Skip to content

Midas Rex Legend AF03

by Medtronic Powered Surgical Solutions

Ref AF03

Midas Rex Legend AF03 is a burring power tool attachment (EU MDR Class IIa; FDA Class II; FDA product code HBB, Motor, Drill, Pneumatic) made by Medtronic Powered Surgical Solutions, registered in EUDAMED on 25 Sep 2026 (Basic UDI-DI 0763000B000136886), cleared under FDA 510(k) K020069 on 18 Mar 2002 and listed in FDA GUDID since 16 Dec 2021 (UDI-DI 00763000440404), active as of 25 Oct 2026. 8 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

9 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K020069

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B000136886 Basic UDI-DI 00763000440404UDI-DIDate25 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00763000440404 UDI-DI Date16 Dec 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK020069 Date18 Mar 2002DecidedStatusActive

Official records

From the FDA record

Device description
ATT AF03 LEGEND FOOTED F3-S 3.2MM
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Ethylene Oxide)

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0763000B000136886 registered 25 Sep 2026 Active
  • FDA 510(k) K020069 decided 18 Mar 2002 Active
  • FDA GUDID UDI-DI 00763000440404 listed 16 Dec 2021 Listed

Recalls

9 recalls · FDA

    • Terminated Z-1602-2016 FDA Class II initiated 8 Apr 2016

    Incorrect color coding and attachment reference were included on the labeling of 10BA40D dissecting tools with lot number H5237248.

    • Terminated Z-0321-2016 FDA Class II initiated 21 Oct 2015

    The wire pass hole is not present on the tools.

    • Terminated Z-0546-2010 FDA Unclassified (pre-2012) initiated 30 Nov 2009

    Component of product attachment may be outside established tolerance with potential for footed portion to break during normal use.

    • Terminated Z-2156-2008 FDA Unclassified (pre-2012) initiated 30 May 2008

    Cutting flute geometry of surgical dissecting tools may be outside of established tolerance. This may lead to reduced cutting performance, inability to perform desired dissection, increased risk of overheating, and potential need for revision surgery.

    • Terminated Z-1574-05 FDA Unclassified (pre-2012) initiated 1 Sep 2005 on shared 510(k) K020069

    Potential compromise of sterile packaging for disposable dissecting tools.

    • Terminated Z-1067-05 FDA Unclassified (pre-2012) initiated 29 Jun 2005

    Complaints of finger control component breaking off and falling into open surgical wound.

    • Terminated Z-0278-05 FDA Unclassified (pre-2012) initiated 11 Nov 2004

    Softer hose increases the propensity for outer exhaust hose to kink or become occluded as a result of clamping. Complaints of hose rupture/burst have been reported.

    • Terminated Z-0213-05 FDA Unclassified (pre-2012) initiated 3 Nov 2004

    Reduced plastic thickness of lubricant/diffuser cartidge can crack under pressure causing leakage of lubricant as visible mist (appearance of smoke).

    • Terminated Z-0419-03 FDA Unclassified (pre-2012) initiated 11 Nov 2002

    Lubricant leaking from motor after sterilization causing bleed-through sterilization wrap and/or excess lubricant in instrument case.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

12 dated events

  1. Recall initiated FDA recalls Z-0213-05
  2. Recall initiated FDA recalls Z-0278-05
  3. Recall initiated FDA recalls Z-1067-05
  4. Recall initiated FDA recalls Z-1574-05
  5. Recall initiated FDA recalls Z-2156-2008
  6. Recall initiated FDA recalls Z-0546-2010
  7. Recall initiated FDA recalls Z-0321-2016
  8. Recall initiated FDA recalls Z-1602-2016
  9. Listed FDA GUDID 00763000440404
  10. Registered EUDAMED 0763000B000136886

2 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Midas Rex Legend
Generic name
Burring power tool attachment
Device name
Legend Footed Attachment
Model / reference
AF03
Primary DI / UDI-DI
00763000440404
Basic UDI-DI
0763000B000136886
510(k) Number
FDA product code
HBB
EMDN code
Z12100980 Instruments for motorised neurosurgery systems - hardware accessories
GMDN term
Burring power tool attachment
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
882.4370
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Ethylene Oxide

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under INSTRUMENTS FOR MOTORISED NEUROSURGERY SYSTEMS - HARDWARE ACCESSORIES.

Other devices from Medtronic Powered Surgical Solutions

See all devices from Medtronic Powered Surgical Solutions →

Properties

  • Sterilise before use
  • Prescription use
  • Serial number
Other properties (22, all answered No)