Midas Rex® AVS10 is a Class II device made by Medtronic Powered Surgical Solutions, cleared under FDA 510(k) K020069 on 18 Mar 2002 and listed in FDA GUDID since 26 Jun 2016 (UDI-DI 00613994468833), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00613994468833 | Date26 Jun 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK020069 | Date18 Mar 2002 | StatusActive |
Official records
- AccessGUDID record 00613994468833
- FDA 510(k) database K020069
Across registries
- FDA 510(k) K020069 decided 18 Mar 2002 Active
- FDA GUDID UDI-DI 00613994468833 listed 26 Jun 2016 Listed
Recalls
-
- Terminated Z-1602-2016
Incorrect color coding and attachment reference were included on the labeling of 10BA40D dissecting tools with lot number H5237248.
-
- Terminated Z-0321-2016
The wire pass hole is not present on the tools.
-
- Terminated Z-0546-2010
Component of product attachment may be outside established tolerance with potential for footed portion to break during normal use.
-
- Terminated Z-2156-2008
Cutting flute geometry of surgical dissecting tools may be outside of established tolerance. This may lead to reduced cutting performance, inability to perform desired dissection, increased risk of overheating, and potential need for revision surgery.
-
- Terminated Z-1574-05
Potential compromise of sterile packaging for disposable dissecting tools.
-
- Terminated Z-1067-05
Complaints of finger control component breaking off and falling into open surgical wound.
-
- Terminated Z-0278-05
Softer hose increases the propensity for outer exhaust hose to kink or become occluded as a result of clamping. Complaints of hose rupture/burst have been reported.
-
- Terminated Z-0213-05
Reduced plastic thickness of lubricant/diffuser cartidge can crack under pressure causing leakage of lubricant as visible mist (appearance of smoke).
-
- Terminated Z-0419-03
Lubricant leaking from motor after sterilization causing bleed-through sterilization wrap and/or excess lubricant in instrument case.
Timeline
- Recall initiated FDA recalls Z-0419-03
- Recall initiated FDA recalls Z-0213-05
- Recall initiated FDA recalls Z-0278-05
- Recall initiated FDA recalls Z-1067-05
- Recall initiated FDA recalls Z-1574-05
- Recall initiated FDA recalls Z-2156-2008
- Recall initiated FDA recalls Z-0546-2010
- Recall initiated FDA recalls Z-0321-2016
- Recall initiated FDA recalls Z-1602-2016
- Listed FDA GUDID 00613994468833
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Midas Rex®
- Generic name
- Burring power tool attachment
- Model / reference
- AVS10
- Primary DI / UDI-DI
- 00613994468833
- 510(k) Number
- FDA product code
- HBB
- GMDN term
- Burring power tool attachment
- Device class
- Class II
- Regulation number
- 882.4370
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices in this category