Skip to content

mintLesion® 3.6.0

by Mint Medical GmbH

mintLesion 3.6.0 is a radiological PACS-dedicated management software (FDA Class II; FDA product code LLZ, System, Image Processing, Radiological) made by Mint Medical GmbH, cleared under FDA 510(k) K142647 on 13 Apr 2015 and listed in FDA GUDID since 29 Oct 2019 (UDI-DI 04260495880365), active as of 23 Oct 2026. 3 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

510(k) K142647

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number04260495880365 UDI-DI Date29 Oct 2019ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) from GUDID NumberK142647 Date13 Apr 2015IssuedStatusActive

Official records

From the FDA record

Device description
The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K142647 decided 13 Apr 2015 Active
  • FDA GUDID UDI-DI 04260495880365 listed 29 Oct 2019 Listed

Recalls

3 recalls · 3 ongoing · FDA

    • Ongoing Z-2068-2026 FDA Class II initiated 7 Jan 2026 UDI-DI 04260495880365 listed

    If the connection between a mint Lesion workstation and the mint Lesion server is interrupted while performing a read, in rare cases some information may be lost or incorrectly linked to other patients.

  • 2 recalls, same reason

    • Ongoing Z-0709-2025 FDA Class II initiated 15 Nov 2024
    • Ongoing Z-0710-2025 FDA Class II initiated 15 Nov 2024

    Some software versions have a malfunction where they may show incorrect orientation labels for a specific subset of DICOM images.

Timeline

5 dated events

  1. Cleared FDA 510(k) K142647
  2. Listed FDA GUDID 04260495880365
  3. Recall initiated FDA recalls Z-0709-2025
  4. Recall initiated FDA recalls Z-0710-2025
  5. Recall initiated FDA recalls Z-2068-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
mintLesion®
Generic name
Radiological PACS-dedicated management software
Model / reference
3.6.0
Primary DI / UDI-DI
04260495880365
510(k) Number
FDA product code
LLZ
GMDN term
Radiological PACS-dedicated management software
Device class
Class II
Regulation number
892.2050
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Radiological PACS software.

Other devices from Mint Medical GmbH

  • mintLesion® 3.7.0 Open recall

    Class II
  • mintLesion® 3.5.0 Open recall

    Class II
  • mintLesion® 3.4.0 Open recall

    Class II
  • mintLesion® 3.3.0 Open recall

    Class II

See all devices from Mint Medical GmbH →

Properties

  • Lot / batch number
  • Manufacturing date
Other properties (13, all answered No)