Skip to content

MLA Electra 700

by Medical Laboratory Automation Systems, Inc.

510(k) K812124

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK812124 Date2 Oct 1981ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JPA
Device Class
Class II
Regulation
21 CFR Part 864.5425
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The MLA Electra 700 is a System, Multipurpose for In Vitro Coagulation Studies, designed to automate and measure clot formation time in blood plasma samples. Utilizing photometric clot detection, it provides precise timing for coagulation assays, supporting hematology diagnostics. This device is classified under FDA regulation 864.5425 and falls within Class II medical devices, ensuring compliance with stringent performance standards.

Intended for use in clinical laboratory settings, the MLA Electra 700 operates as a reusable instrument, requiring no sterilization between uses. It is not MRI-safe and must be used in environments free from electromagnetic interference. The system is authorized under FDA 510(k) clearance (K812124) and is regulated under the Hematology advisory committee. No single-use or sterile packaging is specified, and storage conditions are not detailed in the available data.

Other devices from Medical Laboratory Automation Systems, Inc.

See all devices from Medical Laboratory Automation Systems, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the MLA Electra 700 used for?

    The MLA Electra 700 is a reusable multipurpose system designed specifically for in vitro coagulation studies. It automates and measures clot formation time in blood plasma samples using photometric clot detection, which is essential for accurate hematology diagnostics. This device supports clinical laboratories by providing precise timing for coagulation assays, helping clinicians assess bleeding disorders, monitor anticoagulant therapy, and diagnose other hematological conditions.

  • Is the MLA Electra 700 single-use or reusable?

    The MLA Electra 700 is a reusable instrument. It is not intended to be sterilized between uses, as it is designed for repeated clinical application in controlled laboratory environments. This design ensures durability and cost-effectiveness for long-term use in hematology diagnostics.

  • What safety considerations should be noted when using the MLA Electra 700?

    The MLA Electra 700 must be used in environments free from electromagnetic interference, as it is not MRI-safe. This ensures accurate and reliable performance of coagulation assays. Additionally, since it is a reusable device, proper cleaning and maintenance protocols must be followed to prevent cross-contamination and ensure consistent results.

  • What regulatory pathway does the MLA Electra 700 follow?

    The MLA Electra 700 is authorized under FDA 510(k) clearance (K812124) and classified under FDA regulation 864.5425 as a Class II medical device. It was determined to be substantially equivalent to a predicate device and falls under the Hematology advisory committee’s jurisdiction. This regulatory pathway ensures compliance with stringent performance standards for coagulation testing systems.

  • Are there specific storage conditions mentioned for the MLA Electra 700?

    The provided documentation does not specify detailed storage conditions for the MLA Electra 700. However, as a reusable medical device, it should be stored in a clean, dry environment to prevent damage or contamination. Proper maintenance and calibration procedures should also be followed to ensure optimal performance and longevity.