Skip to content

Model 329T Programmable, Bipolar Cardi

by Cook Pacemaker Corp.

510(k) K832893

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK832893 Date4 Oct 1983ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Model 329T Programmable, Bipolar Cardi is an Implantable Pacemaker Pulse-Generator, designed to regulate heart rhythm by delivering electrical impulses to the heart muscle when necessary. This device is classified as a Class III medical device under FDA regulations, intended for patients with bradycardia or other cardiac conduction disorders requiring consistent pacing support.

This programmable pacemaker is intended for surgical implantation and is supplied sterile for single-use. It operates in a bipolar configuration, ensuring precise pacing while minimizing tissue stimulation. The device is regulated under FDA 510(k) clearance (K832893) and adheres to the regulatory requirements outlined in 21 CFR 870.3610. No MRI safety information is specified, and it is not intended for reusable applications.

Other devices from Cook Pacemaker Corp.

See all devices from Cook Pacemaker Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical purpose of the Model 329T Programmable, Bipolar Cardi pacemaker, and who is it designed for?

    The Model 329T is designed to regulate heart rhythm by delivering electrical impulses to the heart muscle, specifically for patients with bradycardia or other cardiac conduction disorders requiring consistent pacing support. It is intended for surgical implantation and provides programmable pacing to ensure precise and reliable heart function.

  • Is the Model 329T meant for reuse, or is it a single-use device, and how is it supplied?

    The Model 329T is supplied sterile and intended for single-use only. It is not designed for reuse, which aligns with its classification as an implantable device requiring sterile conditions during and after surgical implantation.

  • What type of regulatory clearance does the Model 329T hold, and what does this mean for its use?

    The Model 329T holds FDA 510(k) clearance (K832893) under the traditional review pathway, meaning it has been determined to be substantially equivalent to a legally marketed device. This clearance confirms its compliance with FDA regulations for use as an implantable pacemaker pulse-generator, ensuring safety and effectiveness for its intended clinical purpose.

  • Does the Model 329T have any specific configuration that affects how it interacts with the heart?

    Yes, the Model 329T operates in a bipolar configuration, which means it delivers pacing impulses through two electrodes. This design minimizes tissue stimulation while ensuring precise pacing, reducing potential discomfort or complications for the patient.

  • What storage or handling considerations should be taken into account for the Model 329T before implantation?

    Since the Model 329T is supplied sterile and intended for single-use, it must be stored in its original packaging until ready for use to maintain sterility. Proper handling and adherence to sterile procedures are critical to prevent contamination before surgical implantation.