Model 431-02 Biopore Implantable Pacing Lead
by Intermedics, Inc. 510(k)
Active
510(k) K862257
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK862257 | Date10 Jul 1986 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 22 Oct 2026.
Specification
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Model 431-02 Biopore Implantable Pacing Lead is a Permanent Pacemaker Electrode, designed for transvenous implantation to stimulate the heart and regulate cardiac rhythm. It delivers electrical impulses to the right ventricle or atrium via a flexible, insulated conductor, facilitating pacing therapy for patients with bradycardia or conduction disorders. The lead incorporates a Biopore coating to promote tissue integration and reduce fibrosis, enhancing long-term stability and performance.
This lead is supplied sterile and intended for single-use implantation by qualified healthcare professionals in clinical settings such as cardiac catheterization labs or operating rooms. It is classified as a Class III device under FDA regulations (870.3680) and requires professional handling to ensure proper positioning and connection to a pacemaker pulse generator. The device is MRI-unspecified and must be used with caution in magnetic resonance environments. Storage instructions specify protection from moisture and extreme temperatures to maintain sterility and functionality.
Other devices from Intermedics, Inc.
Questions
AI-generated answers, 18 Sep 2026
What is the primary purpose of the Model 431-02 Biopore Implantable Pacing Lead, and how does the Biopore coating benefit patients?
The Model 431-02 Biopore Implantable Pacing Lead is designed for transvenous implantation to deliver electrical pacing impulses to the heart, specifically targeting the right ventricle or atrium. This helps regulate cardiac rhythm in patients with bradycardia or conduction disorders. The Biopore coating promotes better tissue integration and reduces fibrosis, which improves long-term stability and performance of the lead by minimizing complications like lead displacement or failure over time.
Is this device intended for reuse, or is it meant to be used only once? How should it be handled to maintain sterility?
The Model 431-02 Biopore Implantable Pacing Lead is supplied sterile and intended for single-use implantation only. To maintain sterility, it must be handled in a controlled clinical environment, such as a cardiac catheterization lab or operating room, and protected from moisture and extreme temperatures as specified in the storage instructions. Single-use ensures patient safety and reduces the risk of infection or contamination.
What precautions should clinicians take when using this lead in a magnetic resonance (MRI) environment?
The Model 431-02 Biopore Implantable Pacing Lead is labeled as MRI-unspecified, meaning its safety in MRI environments has not been fully established. Clinicians must exercise extreme caution when considering MRI procedures for patients with this lead implanted. Consultation with a cardiologist or MRI facility is strongly advised to assess potential risks, as improper use could lead to device malfunction or patient harm.
How is this device classified under FDA regulations, and what does that mean for its use in clinical settings?
The Model 431-02 Biopore Implantable Pacing Lead is classified as a Class III device under FDA regulations (870.3680), which means it is subject to stringent premarket approval requirements due to its high-risk nature. This classification ensures that the device undergoes rigorous evaluation for safety and effectiveness before use. Clinicians must follow FDA guidelines and manufacturer instructions to ensure proper implantation, positioning, and connection to a pacemaker pulse generator, as it requires professional handling.
What types of clinical settings are appropriate for implantation of this pacing lead, and why?
This lead is intended for implantation in clinical settings such as cardiac catheterization labs or operating rooms, where qualified healthcare professionals can ensure sterile conditions and precise placement. These environments provide the necessary infrastructure, expertise, and monitoring capabilities to safely perform transvenous lead implantation, reduce infection risks, and confirm proper function before connecting it to a pacemaker pulse generator.