Model 675GE-64 Peripheral Vascular Coil Consisting of Model 665GE-64: Lower Extremity Flexible Array and Model 538GE-64:
510(k) K964813
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK964813 | Date26 Feb 1997 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- MOS
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1000
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
This device is a Magnetic Resonance, Specialty Coil designed for peripheral vascular imaging. It consists of a flexible array coil (Model 665GE-64) and a dedicated coil (Model 538GE-64) tailored for lower extremity applications. The coil assembly enhances signal reception in vascular structures, improving visualization of blood vessels in the legs and feet during MRI scans.
The Model 675GE-64 is supplied as a reusable, non-sterile device intended for use in MRI-compatible environments. It is classified as a Class II medical device under FDA regulations (21 CFR 892.1000) and holds a FDA 510K clearance (K964813) with a Substantially Equivalent determination by the Radiology Advisory Committee. Storage requires protection from electromagnetic interference and physical damage, adhering to standard MRI coil maintenance protocols.
Other devices from Medical Advances, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Model 675GE-64 Peripheral Vascular Coil used for?
The Model 675GE-64 Peripheral Vascular Coil is designed specifically for Magnetic Resonance (MRI) imaging of peripheral vascular structures. It consists of a flexible array coil (Model 665GE-64) and a dedicated coil (Model 538GE-64) tailored to enhance signal reception in blood vessels of the lower extremities, such as the legs and feet. This improves the clarity and detail of vascular imaging, aiding in the diagnosis of conditions like peripheral artery disease.
Is the Model 675GE-64 coil reusable or single-use?
The Model 675GE-64 Peripheral Vascular Coil is supplied as a reusable device. It is not intended for single-use applications. Reusability is suitable for clinical environments where proper cleaning, maintenance, and storage protocols are followed to ensure consistent performance and patient safety.
What are the key storage requirements for this MRI coil?
The Model 675GE-64 coil must be stored in a way that protects it from electromagnetic interference and physical damage. Since it is designed for MRI-compatible environments, it should be kept in a location free from strong magnetic fields or sources of interference that could compromise its functionality. Adherence to standard MRI coil maintenance protocols is essential to preserve its performance and longevity.
What regulatory status does the Model 675GE-64 hold?
The Model 675GE-64 Peripheral Vascular Coil holds a FDA 510K clearance (K964813) with a Substantially Equivalent determination by the Radiology Advisory Committee. It is classified as a Class II medical device under 21 CFR 892.1000, indicating it has undergone regulatory review for safety and effectiveness in its intended use.
How does the flexible array design benefit lower extremity imaging?
The flexible array coil (Model 665GE-64) in the Model 675GE-64 is engineered to conform closely to the contours of the lower extremities. This design reduces signal loss and improves uniformity of magnetic field reception across the vascular structures, resulting in higher-resolution images of blood vessels in the legs and feet. The dedicated coil (Model 538GE-64) further optimizes signal clarity for targeted vascular imaging.