Skip to content

Model 8500 Handheld Pulse Oximeter

by Nonin Medical, Inc.

Ref 113303-001Model MODEL 8500, 8000AA PULSE OXIMETER

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), GUDID, synced 24 Oct 2026. What this means

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00849686051698 Basic UDI-DI 00849686051698UDI-DIDate10 Dec 2024RegisteredStatusActive
United StatesGUDID listing GUDID Number00849686051698 UDI-DI Date17 Sep 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK001930 Date20 Jul 2000IssuedStatusActive

Certificates

0 certificates · EUDAMED

EUDAMED lists no certificate for this device's Basic UDI-DI.

A certificate issued for a device group may exist without being linked here.

Recalls

1 recall · FDA

    • Terminated Z-1690-2017 FDA Class II initiated 29 Sep 2016

    Nonin manufactures and sells two 8500 handheld pulse oximeters (Model 8500 with no memory feature and the 8500M which has a memory feature). Some of the devices distributed may not have the correct pulse oximetry board with the integrated memory feature.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDD Active

Specification

EUDAMED · 510(k) · GUDID

Trade Name
Model 8500 Handheld Pulse Oximeter EUDAMED
Handheld Pulse Oximeter GUDID
Generic Name
Pulse oximeter
Model / Reference
MODEL 8500 EUDAMED
8000AA PULSE OXIMETER EUDAMED
113303-001 EUDAMED
8500 GUDID
PULSE OXIMETER GUDID
Primary DI / UDI-DI
00849686051698
Basic UDI-DI
B-00849686051698
FDA Product Code
DQA
EMDN Code
C900301 Pulse oximeter sensors
GMDN Term
Pulse oximeter
Device Class
Class IIb EUDAMED
Class II GUDID
Regulation Number
870.2700
Market of Registration
Netherlands
GUDID distribution status
In Commercial Distribution
MRI Safety
MR Unsafe

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / ReferenceEUDAMED
MODEL 8500, 8000AA PULSE OXIMETER
113303-001
GUDID
8500, PULSE OXIMETER
Device ClassEUDAMED
Class IIb
GUDID
Class II

Manufacturer details

EUDAMED SRN
US-MF-000008228
Authorised representative
MPS Medical Product Service GmbH DE-AR-000005009

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Model 8500 Handheld Pulse Oximeter is a non-invasive diagnostic device classified under nomenclature code C900301, designed to measure oxygen saturation (SpO₂) and pulse rate. It employs photoplethysmography to continuously monitor arterial oxygen levels and heart rate via a sensor placed on a patient’s finger, toe, or earlobe, providing real-time physiological data for clinical assessment.

This device is intended for single-use applications in non-sterile settings, including emergency medical services, homecare, and pre-hospital environments. Supplied as a non-reusable, non-implantable Class IIb medical device, it operates with measurement wavelengths of 660 nm (red) and 910 nm (infrared), with maximum average output powers of 0.8 mW and 1.2 mW, respectively. Authorized under FDA 510K and MDD compliance, it is distributed under UDI B-00849686051698 and is intended for use with compatible sensors as specified in Nonin’s documentation.

Other devices from Nonin Medical, Inc.

See all devices from Nonin Medical, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Is the Model 8500 Handheld Pulse Oximeter designed for reusable use in clinical settings, or is it intended for single-use only?

    The Model 8500 Handheld Pulse Oximeter is explicitly designed for single-use applications in non-sterile environments like emergency medical services, homecare, or pre-hospital care. The device is classified as non-reusable (REUSABLE: 0) and is not intended for reprocessing or reuse, as confirmed by its specifications.

  • What types of body locations can the Model 8500 Handheld Pulse Oximeter be used on, and how does it measure oxygen saturation?

    The Model 8500 uses photoplethysmography to measure oxygen saturation (SpO₂) and pulse rate by placing a sensor on a patient’s finger, toe, or earlobe. It continuously monitors arterial oxygen levels and heart rate in real-time, providing physiological data for clinical assessment without invasive procedures.

  • What are the key wavelengths and power outputs used by the Model 8500 Handheld Pulse Oximeter, and how does this affect its functionality?

    The device employs 660 nm (red) and 910 nm (infrared) wavelengths to measure blood oxygenation and pulse rate. The maximum average output powers are 0.8 mW for red and 1.2 mW for infrared, ensuring accurate and reliable readings through non-invasive light absorption analysis in tissue.

  • How is the Model 8500 Handheld Pulse Oximeter distributed, and what unique device identifier (UDI) should buyers reference when ordering?

    The Model 8500 is distributed under the UDI B-00849686051698 (with associated UDI-DI data). Buyers should reference this identifier for traceability and compliance, as it aligns with the device’s regulatory submission and global market distribution through authorized distributors like MPS Medical Product Service GmbH.

  • Is the Model 8500 Handheld Pulse Oximeter compatible with all sensor types, or does it require specific sensors for accurate readings?

    The Model 8500 is intended for use with compatible sensors as specified in Nonin’s documentation. While the device itself is non-reusable, the sensors may vary in design or attachment method, so clinicians should confirm compatibility with Nonin’s guidelines to ensure accurate SpO₂ and pulse rate measurements.

Properties

  • Measuring Function
  • Serial Number
  • Manufacturing Date

Other properties (19)

  • Sterile: No
  • Single Use: No
  • Implantable: No
  • Reusable: No
  • Contains Latex: No
  • Reprocessed: No
  • Human-derived: No
  • Human Tissues: No
  • Animal Tissues: No
  • Administering Medicine: No
  • Incorporates Medicinal Product: No
  • Prescription Use: No
  • Over-the-Counter: No
  • Convenience Kit: No
  • Combination Product: No
  • HCT/P: No
  • Premarket Exempt: No
  • Lot / Batch Number: No
  • Expiration Date: No