Skip to content

Model 8700 Bipolar Electrosurgical Generator

by Everest Medical Corp. 510(k)

Active United States

510(k) K870981

Overview

The Model 8700 Bipolar Electrosurgical Generator is an electrosurgical unit designed to provide cutting and coagulation energy using bipolar technology. It delivers controlled electrical current for tissue dissection and hemostasis in surgical procedures.

The device was cleared by the FDA through a traditional 510(k) submission (K870981) as substantially equivalent to a predicate device, classified under product code GEI as a Class II electrosurgical accessory for general and plastic surgery. It is supplied by Everest Medical Corp. and identified by the model number 8700; no sterility or single‑use information is provided in the data.

AI-generated from registry data, 22 Sep 2026.Not verified by deviCERTS or the manufacturer

Regulatory status

as of 28 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK870981 Date6 May 1987ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
GEI
Device Class
Class II
Regulation
21 CFR Part 878.4400
Advisory Committee
General, Plastic Surgery
FDA Decision
SESE Substantially Equivalent

Other devices from Everest Medical Corp.

See all devices from Everest Medical Corp. →

Questions

  • What surgical applications is the Model 8700 designed for?

    The Model 8700 is intended for use in general and plastic surgery procedures where precise tissue dissection and reliable hemostasis are required. Its bipolar technology allows surgeons to cut and coagulate simultaneously, reducing the need for separate instruments and improving workflow in these specialties.

  • How is the Model 8700 supplied and is it sterile?

    The generator is supplied by Everest Medical Corp. as a non‑sterile unit; the data does not specify any sterility labeling or single‑use status. Because it is an electrosurgical generator, it is typically used in the operating room with sterile handpieces that are attached separately.

  • Is the Model 8700 a single‑use device or can it be reused?

    The information provided does not indicate a single‑use designation, so the generator itself is a reusable piece of equipment. Clinical practice usually involves reprocessing the unit according to the manufacturer’s maintenance guidelines, while any disposable accessories would be handled separately.

  • What regulatory pathway was used for the Model 8700 clearance?

    The Model 8700 received FDA clearance through a traditional 510(k) submission (K870981), demonstrating substantial equivalence to a predicate electrosurgical accessory. This pathway classifies the device as a Class II product under product code GEI.