Device (019B +5 more) - 019J
by Advanced Medical Optics, Inc.
PMA P810055
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA PMAAPPR | NumberP810055 | Date3 May 1983 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Generic Name
- intraocular lens
- PMA Number
- FDA Product Code
- HQL
- Device Class
- Class III
- Regulation
- 21 CFR Part 886.3600
- Advisory Committee
- Ophthalmic
- FDA Decision
- APPR Approved
- PMA Supplement
- S002
Overview
AI-generated summary, 18 Sep 2026
This device is an intraocular lens, a prosthetic implant designed to replace the natural lens of the eye following cataract surgery or other conditions requiring lens removal. It is classified as a Class III medical device under FDA regulations, requiring premarket approval due to its role in restoring visual function and correcting refractive errors.
The Models 019B, 019C, 019E, 019F, 019J, and 019K intraocular lenses are intended for single-use implantation during ophthalmic procedures. They are supplied sterile and fall under the product code HQL, regulated under FDA regulation number 886.3600. Approved via Premarket Approval (PMA) P810055, these lenses are manufactured by Advanced Medical Optics, Inc., and are distributed for use in controlled surgical environments.
Other devices from Advanced Medical Optics, Inc.
Questions
AI-generated answers, 18 Sep 2026
Are these intraocular lenses reusable or intended for single-use only?
These intraocular lenses (Models 019B, 019C, 019E, 019F, 019J, and 019K) are explicitly designed for **single-use implantation** during ophthalmic procedures. The manufacturer, Advanced Medical Optics, Inc., supplies them sterile for one-time surgical use only, ensuring patient safety and compliance with sterile field protocols in controlled environments.
How are these lenses stored, and what should clinicians consider before use?
The lenses are supplied **sterile** and must be stored according to the manufacturer’s instructions to maintain integrity. Since they are single-use, clinicians should verify the packaging is intact and unopened before use. Proper storage conditions (e.g., dry, protected from light, and within expiration dates) are critical to preserve sterility and functionality. Always follow the included storage guidelines to avoid contamination or degradation.
What regulatory pathway was followed for approval of these intraocular lenses?
These lenses were approved via the **FDA Premarket Approval (PMA) process**, specifically under PMA number **P810055**. The device falls under **product code HQL** and is classified as a **Class III** medical device, requiring rigorous clinical and safety evaluations before approval. This pathway ensures the lenses meet stringent standards for restoring visual function and correcting refractive errors.
Are there different models available, and if so, how do they differ?
Yes, there are **six distinct models** (019B, 019C, 019E, 019F, 019J, and 019K) listed for these intraocular lenses. While the data provided does not specify exact differences in optical power, design, or refractive correction, the models are likely tailored for varying clinical needs such as aphakia correction, astigmatism management, or specific patient anatomies. Consult the manufacturer’s technical documentation for precise model-specific details, as these distinctions are critical for surgical planning.
What should a buyer or hospital verify before purchasing these lenses?
Before purchasing, buyers should confirm the **sterility status** of the packaging and verify the **expiration date** to ensure the lenses are within their usable range. Additionally, they should confirm compatibility with their surgical equipment and procedures, as well as check that the lenses align with their facility’s **ophthalmic protocols** for cataract surgery or lens replacement. Since these are **single-use**, inventory management should account for surgical volume and turnover rates.