Skip to content

Modification of Sterility Cycle Parameters (K863365)

by Coratomic, Inc.

510(k) K863365

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK863365 Date8 Oct 1986ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Modification of Sterility Cycle Parameters
510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is an Implantable Pacemaker Pulse-Generator, classified as a Class III medical device under FDA regulations. It involves adjustments to sterilization cycle parameters to ensure the device meets required sterility standards for implantation, maintaining its integrity and safety for cardiovascular use.

The device is supplied as a reusable medical component, regulated under FDA 510(k) clearance (K863365) and filed under product code DXY. Sterilization modifications are validated to achieve consistent sterility assurance, adhering to regulation number 870.3610. It is intended for use in cardiovascular procedures and is subject to traditional review by the FDA’s Cardiovascular (CV) advisory committee.

Other devices from Coratomic, Inc.

See all devices from Coratomic, Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What type of device is this modification related to, and how is it used clinically?

    This modification pertains to an Implantable Pacemaker Pulse-Generator, a Class III medical device used in cardiovascular procedures. The device is implanted to regulate heart rhythms by delivering electrical impulses when the heart’s natural pacemaker isn’t functioning properly. The sterilization adjustments ensure the device remains safe and sterile for implantation, maintaining its integrity for long-term use in patients.

  • Is this device single-use or reusable, and how is it sterilized?

    This device is reusable, as explicitly stated in the submission. The modification involves adjustments to the sterilization cycle parameters to ensure it meets strict sterility standards (per FDA regulation 870.3610) before reuse in cardiovascular procedures. The validated process guarantees consistent sterility assurance for repeated use.

  • What regulatory pathway was followed for this modification, and which advisory committee reviewed it?

    This modification was submitted under the FDA 510(k) pathway (clearance number K863365) and underwent traditional review by the FDA’s Cardiovascular (CV) Advisory Committee. The submission was classified as substantially equivalent (SESE) and filed under product code DXY, confirming compliance with regulatory requirements for implantable cardiovascular devices.

  • How many different models or versions of this device are associated with this modification?

    This modification applies to multiple versions of an Implantable Pacemaker Pulse-Generator, as indicated by the 18 distinct FEI numbers (e.g., 3002807576, 2017865, etc.) listed in the submission. Each FEI represents a unique device variant, all of which benefit from the updated sterilization cycle to maintain sterility and safety for reuse.