Skip to content

AciST CL 100H Modification

by ACIST Medical Systems, Inc.

510(k) K991103

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

3 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK991103 Date31 May 2000ClearedStatusActive

Recalls

3 recalls · FDA

    • Terminated Z-0643-2009 FDA Unclassified (pre-2012) initiated 10 Nov 2008

    Multiple Injections may result. It has been determined that when using the ACIST CVi Angiographic Injection system to synchronize with the Toshiba Infinix -i cardiovascular x-ray system there is an injection scenario that may result in multiple injections of contract media when one injection was intended.

    • Terminated Z-1002-04 FDA Unclassified (pre-2012) initiated 19 May 2004

    Some of the sterile product packages were inadequately sealed prior to sterilization and as a result the package contents may not be sterile.

    • Terminated Z-0064-04 FDA Unclassified (pre-2012) initiated 2 Oct 2003

    Some of the automated manifold's 2.5 inch high-pressure lines for radiopaque contrast media, used in angiographic procedures, have separated where they are bonded to the manifold body of the device allowing contrast media to leak.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Modification to Acist Cl 100H
510(k) Number
FDA product code
DXT
FDA applicant
Acist Medical Systems
Device class
Class II
Regulation
21 CFR Part 870.1650
Advisory committee
Cardiovascular
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The AciST CL 100H Modification is an angiographic injector and syringe system designed for use in cardiovascular procedures. It is classified as a Class II device under FDA regulations and functions as an electro-mechanical contrast injector, delivering precise contrast media during angiographic imaging in catheterization laboratories.

This device is supplied as a modification to the original AciST CL 100H system and is intended for single-use with disposable components, including a two-port syringe and manifold. It operates within MRI-unsafe environments due to its electro-mechanical components and is regulated under FDA 510(k) clearance (K991103) as a substantially equivalent modification. Storage and handling follow standard sterile medical device protocols for catheter lab use.

Other devices from ACIST Medical Systems, Inc.

See all devices from ACIST Medical Systems, Inc. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of procedures is the AciST CL 100H Modification designed to support in a catheterization lab?

    The AciST CL 100H Modification is specifically designed for use in cardiovascular procedures, particularly those requiring angiographic imaging. It functions as an electro-mechanical contrast injector, delivering precise contrast media during coronary or peripheral angiograms to enhance visualization of blood vessels.

  • Is the AciST CL 100H Modification intended for single-use or reusable applications?

    This modification is intended for single-use with disposable components, including a two-port syringe and manifold. The electro-mechanical base unit is not disposable but is paired with these single-use accessories for each procedure.

  • How is the device regulated, and what does that mean for its use in clinical settings?

    The AciST CL 100H Modification received FDA 510(k) clearance (K991103) as a substantially equivalent modification to the original CL 100H system. This means it has been reviewed and deemed comparable to a previously cleared device, ensuring compliance with FDA standards for safety and effectiveness in angiographic applications.

  • Can this device be used in an MRI environment, and if not, why?

    No, the AciST CL 100H Modification is not MRI-safe due to its electro-mechanical components, which could pose risks in magnetic resonance imaging environments. It is explicitly designed for use in catheterization labs where MRI compatibility is not required.

  • What storage and handling precautions should be taken for the disposable components of this device?

    The disposable components (such as the syringe and manifold) follow standard sterile medical device protocols for catheter lab use. They should be stored in a clean, dry environment, protected from contamination, and handled using aseptic techniques to maintain sterility before use.