Modification to: Minimesh Polypropylene Mesh
by Mpathy Medical Devices, Ltd.
510(k) K053361
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK053361 | Date6 Feb 2006 | StatusActive |
Recalls
-
- Terminated Z-1481-2012
Coloplast is conducting a field correction based on the conclusion that two lots of Restorelle DirectFix Posterior mesh were mislabeled. The incorrect size was printed on the patient label. Specifically the patient label depicts the size as 16x11 cm, however, the correct size is actually 14x15 cm. It is important to note that both the product and box labels were correct.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- OTO
- Device Class
- Class II
- Regulation
- 21 CFR Part 878.3300
- Advisory Committee
- General, Plastic Surgery
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 24 Sep 2026
This device is a surgical mesh made of polypropylene, intended for use in urogynecologic procedures to treat apical vaginal and uterine prolapse. It is designed to be placed transabdominally to provide support for pelvic organ prolapse repair.
The device is supplied as a sterile, single-use implant. It is authorized under FDA 510(k) clearance (K053361) and is classified as a Class II medical device. It is intended for use in surgical settings by trained healthcare professionals.
Other devices from Mpathy Medical Devices, Ltd.
Questions
AI-generated answers, 24 Sep 2026
What clinical condition is this mesh designed to treat?
The mesh is intended for urogynecologic procedures that repair apical vaginal and uterine prolapse, providing transabdominal support to restore pelvic organ position.
How is the product supplied and what are its sterility requirements?
It is supplied as a sterile, single‑use implant, meaning each unit is packaged sterile and intended for one procedure only, eliminating the need for re‑sterilization.
Can the mesh be reused for multiple patients?
No. Because it is labeled as a single‑use device, reusing it would compromise sterility and could increase the risk of infection or tissue reaction.
What regulatory pathway was used for this device?
The device received FDA 510(k) clearance (K053361) with a special clearance type, indicating it was found substantially equivalent to a legally marketed predicate.
Who is authorized to place this mesh during surgery?
Placement is intended for trained healthcare professionals in a surgical setting, typically surgeons experienced in urogynecologic and pelvic reconstructive procedures.