Rx Accunet Embolic Protection System
by Guidant Corporation 510(k)
Active
510(k) K052166
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK052166 | Date18 Aug 2005 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 5 Oct 2026.
Specification
- Full name
- Modification to: Rx Accunet Embolic Protection System
- 510(k) Number
- FDA Product Code
- NTE
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1250
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Rx Accunet Embolic Protection System is a Temporary Carotid Catheter for Embolic Capture, designed to prevent embolic material (thrombus or debris) from dislodging during carotid artery angioplasty and stenting procedures. It functions as both a guide wire and an embolic protection device, deploying a filter basket within the artery to trap particulate matter while maintaining blood flow. The system is intended for use in carotid arteries with diameters ranging from 3.25 mm to 7.0 mm, ensuring compatibility with standard interventional techniques.
This device is supplied as a sterile, single-use system and is intended for use in clinical settings such as catheterization labs. It is classified under FDA regulation 870.1250 and holds a 510(k) clearance for modifications, including minor design refinements to the filter basket strut and enhanced in-process manufacturing testing. The system adheres to Class II medical device standards and is regulated under the National Embolic Protection Technology (NTE) product code. No MRI safety information is specified.
Other devices from Guidant Corp.
Questions
AI-generated answers, 1 Oct 2026
What is the Rx Accunet Embolic Protection System used for?
The Rx Accunet Embolic Protection System is a Temporary Carotid Catheter designed to prevent embolic material—such as thrombus or debris—from dislodging during carotid artery angioplasty and stenting. It deploys a filter basket within the artery to trap particulate matter while maintaining uninterrupted blood flow, reducing the risk of stroke or other complications.
How is the Rx Accunet Embolic Protection System supplied and prepared for use?
The system is supplied as a sterile, single-use device, ensuring it is ready for immediate clinical use in catheterization labs without additional sterilization. This design minimizes contamination risks and aligns with best practices for procedural safety.
What carotid artery diameters is the Rx Accunet Embolic Protection System compatible with?
The device is compatible with carotid arteries ranging from 3.25 mm to 7.0 mm in diameter, allowing flexibility for standard interventional techniques while ensuring proper fit and function during procedures.
Is the Rx Accunet Embolic Protection System reusable, or is it intended for single-use?
The Rx Accunet Embolic Protection System is explicitly designed for single-use only. This prevents cross-contamination between patients and ensures optimal performance, as reuse could compromise sterility and structural integrity.
What regulatory pathway does the Rx Accunet Embolic Protection System follow?
The system holds FDA 510(k) clearance for modifications, including refinements to the filter basket strut and enhanced manufacturing testing. It is classified under FDA regulation 870.1250 and falls under the National Embolic Protection Technology (NTE) product code, adhering to Class II medical device standards.