Skip to content

Models 253-19 & 254-20 Quantum Generators

by Intermedics, Inc. 510(k)

Active United States

510(k) K873528

Regulatory status

as of 29 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK873528 Date9 Oct 1987ClearedStatusActive

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

Full name
Modified Models 253-19 & 254-20 Quantum Generators
510(k) Number
FDA Product Code
DXY
Device Class
Class III
Regulation
21 CFR Part 870.3610
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The device is an Implantable Pacemaker Pulse-Generator, a component of cardiac pacemaker systems designed to deliver electrical impulses to regulate heart rhythm in patients with bradycardia or conduction disorders. These pulse-generators are intended for subcutaneous or intrathoracic implantation and provide programmable pacing functions to maintain cardiac output when native conduction fails.

The Models 253-19 & 254-20 Quantum Generators are supplied as sterile, single-use devices for surgical implantation by qualified healthcare professionals. They are classified as Class III medical devices under FDA regulations (870.3610) and were granted FDA 510K clearance via the Traditional pathway, with a decision of Substantially Equivalent to a predicate device. Storage and handling must comply with sterile medical device protocols, and compatibility with MRI environments is not specified in the regulatory data.

Other devices from Intermedics, Inc.

See all devices from Intermedics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these pulse-generators designed for use in patients with specific heart conditions, and if so, which ones?

    These devices, the Models 253-19 & 254-20 Quantum Generators, are intended for patients with bradycardia or conduction disorders where the heart’s natural electrical system fails to maintain adequate cardiac output. They deliver programmable pacing impulses to regulate heart rhythm, either when implanted subcutaneously or intrathoracically.

  • How are these pulse-generators supplied, and what precautions should be taken during handling?

    The pulse-generators are supplied as sterile, single-use devices, meaning each unit is intended for one surgical implantation only. Handling must follow sterile medical device protocols to ensure no contamination occurs before use, as they are not designed for reuse.

  • Are there different models available, and if so, how do they differ?

    Yes, there are two models listed: the 253-19 and the 254-20. While the exact technical differences between them are not specified in the regulatory data, both are classified as Implantable Pacemaker Pulse-Generators and are intended for the same clinical purpose—regulating heart rhythm in patients with bradycardia or conduction disorders.

  • What regulatory pathway was used for FDA clearance, and what does that mean for their use?

    These devices were cleared via the Traditional 510(k) pathway and were determined to be Substantially Equivalent to a predicate device. This means the FDA reviewed them against an existing, legally marketed device to ensure they have the same intended use and safety profile, allowing them to be legally marketed in the U.S. without additional clinical trials.

  • Do these pulse-generators have any known compatibility restrictions, such as with MRI environments?

    The regulatory data does not specify compatibility with MRI environments, so users should consult the manufacturer’s instructions or technical documentation for guidance on safe use in such settings. Always verify compatibility before exposing the device to MRI scans.