Modified Shiley Femoral Arterial Cannula
by Shiley, Inc. 510(k)
Active
510(k) K884393
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK884393 | Date27 Dec 1988 | StatusActive |
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Recalls
No FDA recalls on record, checked 22 Oct 2026.
Specification
- 510(k) Number
- FDA Product Code
- DWF
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.4210
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 6 Oct 2026
A Modified Shiley Femoral Arterial Cannula is a vascular catheter used in cardiopulmonary bypass procedures. It is designed as an arterial cannula with an angled shoulder that limits insertion depth into the artery and forms a seal, and includes suture flaps for skin attachment and a stylet with a stop to prevent blood flow between the cannula and stylet while permitting clamping.
This device received FDA 510(k) clearance (K884393) on December 27, 1988, and is classified as a Class II medical device under regulation number 870.4210. It is supplied by Shiley, Inc. and is intended for use in cardiovascular surgical settings.
Other devices from Shiley, Inc.
Questions
AI-generated answers, 6 Oct 2026
What is the Modified Shiley Femoral Arterial Cannula used for?
The Modified Shiley Femoral Arterial Cannula is a vascular catheter used in cardiopulmonary bypass procedures. It is designed as an arterial cannula with an angled shoulder that limits insertion depth into the artery and forms a seal, and includes suture flaps for skin attachment and a stylet with a stop to prevent blood flow between the cannula and stylet while permitting clamping.
How is the Modified Shiley Femoral Arterial Cannula supplied?
The Modified Shiley Femoral Arterial Cannula is supplied by Shiley, Inc. from their address at 17600 Gillette Ave., P.O. Box 19503, Irvine, CA 92714, United States.
Is the Modified Shiley Femoral Arterial Cannula sterile and for single use?
The device data does not specify whether the Modified Shiley Femoral Arterial Cannula is sterile or intended for single use or reuse. This information is not provided in the authorization or specifications sections.
What regulatory pathway was used for the Modified Shiley Femoral Arterial Cannula?
The Modified Shiley Femoral Arterial Cannula received FDA 510(k) clearance (K884393) on December 27, 1988, and is classified as a Class II medical device under regulation number 870.4210.