Modular handles, HF
by Richard Wolf GmbH 5 variants
Ref 83930084Model 10000201552
Modular handles, HF (83930084) is an endoscopic electrosurgical handpiece/electrode (EU MDR Class I; FDA Class II; FDA product code GCJ, Laparoscope, general & plastic surgery) made by Richard Wolf GmbH, registered in EUDAMED on 18 Nov 2025 (Basic UDI-DI 405520718052021-0000058G5) and listed in FDA GUDID since 28 Sep 2016 (UDI-DI 04055207026656), active as of 22 Oct 2026.
Active
CE MDR
Valid until
No date given
FDA recalls
Not checked
Documents
None linked in EUDAMED
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number405520718052021-0000058G5 04055207026656 | Date18 Nov 2025 | StatusActive |
| United States | GUDID listing GUDID | Number04055207026656 | Date28 Sep 2016 | StatusListed |
Official records
- EUDAMED public site 405520718052021-0000058G5
- AccessGUDID record 04055207026656
From the FDA record
- Device description
- HANDLE AXIAL MONO with monopolar HF connection, for use with all insulated ERAGON outer sheath tubes, reusable
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 405520718052021-0000058G5 registered 18 Nov 2025 Active
- FDA GUDID UDI-DI 04055207026656 listed 28 Sep 2016 Listed
Timeline
- Listed FDA GUDID 04055207026656
- Registered EUDAMED 405520718052021-0000058G5
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Eragon Axial
- Generic name
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device name
- Modular handles, HF
- Model / Ref / Catalog
- 10000201552, 83930084
- Description
- HANDLE AXIAL MONO with monopolar HF connection, for use with all insulated ERAGON outer sheath tubes, reusable
- Primary DI / UDI-DI
- 04055207026656
- Basic UDI-DI
- 405520718052021-0000058G5
- FDA product code
- GCJ
- EMDN code
- L180402 Endoscopic electrosurgery forceps, reusable
- GMDN term
- Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 876.1500
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- DE-MF-000007048
Similar devices in this category
Other devices filed under ENDOSCOPIC ELECTROSURGERY FORCEPS, REUSABLE.
- Guenter Bissinger Medizintechnik GmbH 82460346 by Günter Bissinger Medizintechnik GmbH
- Olympus WA64150L by Olympus Winter & Ibe GmbH
- Guenter Bissinger Medizintechnik GmbH 85500010 by Günter Bissinger Medizintechnik GmbH
- Olympus WA64190A by Olympus Winter & Ibe GmbH
- Gimmi T.0050.19 by Gimmi GmbH
- Gimmi Z.2958.32 by Gimmi GmbH
- MICROSTAN MONOPOLAR FORCEPS IEC-MJ21 by Cynosure, LLC
- BIPOLAR FORCEPS J10 by Cynosure, LLC
- 305mm Crocodile Grasping Forceps 101-48033 by Surgical Innovations Ltd.