Modular Reach Hip
by Biomet, Inc.
510(k) K994038
Active
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK994038 | Date22 Dec 1999 | StatusActive |
Official records
- FDA 510(k) database K994038
From the FDA record
- Received by the FDA
- 29 Nov 1999
- FDA decision
- 22 Dec 1999 (Substantially Equivalent)
- FDA review time
- 23 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA product code
- LPH
- Device class
- Class II
- Regulation
- 21 CFR Part 888.3358
- Advisory committee
- Orthopedic
- FDA decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Modular Reach Hip is a metallic total hip arthroplasty system designed for noncemented femoral fixation. It consists of a proximal body with porous coating for osseointegration, a distal stem, and a Morse locking taper interface secured by a locking screw through a driving platform. The system incorporates Biomet Type I taper modular heads, enabling modularity for customised fit and function. This device is classified under orthopedic implants for hip replacement procedures.
Intended for surgical implantation by orthopedic surgeons, the Modular Reach Hip is supplied as a sterile, single-use implant. It is manufactured from metallic materials, including cobalt-chrome alloys, and is regulated under FDA 510(k) clearance (K994038) with a special review classification. The system is designed for primary hip arthroplasty or revision procedures, adhering to noncemented fixation principles. Storage and handling must comply with sterile medical device protocols to ensure integrity prior to use.
Devices cleared under K994038
Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.
| UDI-DI | Size and differences | |||
|---|---|---|---|---|
| REACH MODULAR HIP SYSTEM 108291 | 108291 / 108291 | 00880304196421 | — | On the market |
| REACH MODULAR HIP SYSTEM 108293 | 108293 / 108293 | 00880304196438 | — | On the market |
| REACH MODULAR HIP SYSTEM 108295 | 108295 / 108295 | 00880304196452 | — | On the market |
| REACH MODULAR HIP SYSTEM 108297 | 108297 / 108297 | 00880304000131 | — | On the market |
| REACH MODULAR HIP SYSTEM 108299 | 108299 / 108299 | 00880304009530 | — | On the market |
| REACH MODULAR HIP SYSTEM 108301 | 108301 / 108301 | 00880304196476 | — | On the market |
| REACH MODULAR HIP SYSTEM 108391 | 108391 / 108391 | 00880304196667 | — | On the market |
| REACH MODULAR HIP SYSTEM 108393 | 108393 / 108393 | 00880304196674 | — | On the market |
| REACH MODULAR HIP SYSTEM 108395 | 108395 / 108395 | 00880304196681 | — | On the market |
| REACH MODULAR HIP SYSTEM 108397 | 108397 / 108397 | 00880304196704 | — | On the market |
| REACH MODULAR HIP SYSTEM 108399 | 108399 / 108399 | 00880304196711 | — | On the market |
| REACH MODULAR HIP SYSTEM 108401 | 108401 / 108401 | 00880304196728 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108291 | 108291 / 108291 | 00880304838888 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108293 | 108293 / 108293 | 00880304838895 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108295 | 108295 / 108295 | 00880304838901 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108297 | 108297 / 108297 | 00880304838918 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108299 | 108299 / 108299 | 00880304838925 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108301 | 108301 / 108301 | 00880304838932 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108391 | 108391 / 108391 | 00880304838949 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108393 | 108393 / 108393 | 00880304838956 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108395 | 108395 / 108395 | 00880304838963 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108397 | 108397 / 108397 | 00880304838970 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108399 | 108399 / 108399 | 00880304838987 | — | On the market |
| REACH® MODULAR HIP SYSTEM 108401 | 108401 / 108401 | 00880304838994 | — | On the market |
Similar devices
Other devices filed under FDA product code LPH (Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented).
- Continuum® Trilogy® 00-8831-013-32 by Zimmer, Inc.
- Trident Large Diameter Acetabular Inserts by Howmedica Osteonics Corp.
- OSS™ 110018679 by Biomet Orthopedics, Inc.
- Biomet® Hip System 163668 by Biomet Orthopedics, Inc.
- Mpact Extension 01.43.0070 by Medacta International SA
- Trabecular Metal® 6202-54-21 00-6202-054-21 by Zimmer, Inc.
- DELTA TT Cup 5552.15.700 by Limacorporate
- DELTA LINERS & ACCESSORIES 5885.54.170 by Limacorporate
- CoCr Femoral Ball Head 01.25.086 by Medacta International SA
- Inter-op Porous Protrusio Shell With Sealable Screwholes by Sulzer Orthopedics, Inc.