by Covidien LP

Mon-a-Therm 90042 is an electronic oesophageal stethoscope (FDA Class II; FDA product code BZT, Stethoscope, Esophageal, with Electrical Conductors) made by Covidien LP, cleared under FDA 510(k) K251025 on 29 Dec 2025 (1 earlier submission) and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 20884521031729), active as of 23 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 23 Oct 2026

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK251025 Date29 Dec 2025DecidedStatusActive
United StatesGUDID listing Number20884521031729 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
Esophageal Stethoscope with Temperature Sensor 400TM
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K251025 decided 29 Dec 2025 Active· +1 more in the status table
  • FDA GUDID UDI-DI 20884521031729 listed 24 Sep 2016 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K811862
  2. Listed FDA GUDID 20884521031729
  3. Cleared FDA 510(k) K251025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Mon-a-Therm
Generic name
Electronic oesophageal stethoscope, single-use
Model / reference
90042
Primary DI / UDI-DI
20884521031729
510(k) Number
FDA product code
BZT
GMDN term
Electronic oesophageal stethoscope, single-use
Device class
Class II
Regulation number
868.1920
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Size
Catheter Gauge — 18 French

Similar devices

Other devices filed under FDA product code BZT (STETHOSCOPE, ESOPHAGEAL, WITH ELECTRICAL CONDUCTORS).

Other devices from Covidien LP

  • Invos PM7100

    Class II
  • Invos PMAC71DOC Open recall

    Class II
  • LigaSure MRASILF19

    Class II
  • Shiley 110860

    Class II

See all devices from Covidien LP →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)